DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-195-2304 to receive an up to date pricing and availability quote by email.

5925-01-195-2304
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-195-2304
Item Name Code
00136
Assigment Date
11/26/1984 (41 years ago)

0.781 inches maximum body length, 0.500 inches nominal center to center distance between terminals parallel to length, 0.593 inches maximum body width, single pole type body style, 0.250 inches nominal bushing length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.250 inches nominal
Body Length
0.781 inches maximum
Body Width
0.593 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.500 inches nominal
Mounting Surface To Terminal End Distance
1.343 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.438 inches
Trip Delay Time In Seconds Per Rated Continuous Current
1.500 minimum at 200 pct and 40.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
vibrationproof
Trip Release Ambient Temp Rating
71.0 fahrenheit nominal single location
Frequency In Hertz
400.0 single location
Material
plastic case
Test Data Document
"81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
un
Terminal Type And Quantity
2 tab w/screw
Specification/Standard Data
96906-ms3320-4v government standard

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-195-2304?
The FSCG of the NSN 5925-01-195-2304 is 5925
Does the NSN 5925-01-195-2304 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-195-2304 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-195-2304 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-195-2304 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-195-2304 was assigned to the Federal Catalog?
It was assigned 41 years ago, on Mon, Nov 26, 1984

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

209-990030-519
5910-00-114-0510
Ceramic Dielectr Fixed Capacitor
209-990030-520
5910-00-305-9515
Ceramic Dielectr Fixed Capacitor
209-990030-521
5910-00-262-5713
Ceramic Dielectr Fixed Capacitor
209-990030-522
5910-00-114-0113
Ceramic Dielectr Fixed Capacitor
209-990030-523
5910-00-113-5278
Ceramic Dielectr Fixed Capacitor
209-990030-533
5910-00-113-5286
Ceramic Dielectr Fixed Capacitor
209-990030-537
5910-00-121-7379
Ceramic Dielectr Fixed Capacitor
209-990060-337
5910-01-144-5394
Capacitor
209-990061-836
5910-01-263-7794
Ceramic Dielectr Fixed Capacitor
209-990070-350
5910-00-912-9662
Ceramic Dielectr Fixed Capacitor
209-990071-142
5910-00-714-2509
Ceramic Dielectr Fixed Capacitor
209-990071-154
5910-00-274-0077
Ceramic Dielectr Fixed Capacitor
209-990071-170
5910-00-004-7786
Ceramic Dielectr Fixed Capacitor
209-990071-396
5910-01-026-5803
Ceramic Dielectr Fixed Capacitor
209-990071-401
5910-01-210-7115
Electrolytic Fixed Capacitor