1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-181-2996

5925-01-181-2996

Find complete technical information, availability, and procurement data for: 5925-01-181-2996

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-181-2996 to receive an up to date pricing and availability quote by email.

5925-01-181-2996
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-181-2996
Item Name Code
00136
Assigment Date
06/08/1984 (42 years ago)

multipole-single actuator type body style, 12.343 inches nominal center to center distance between terminals parallel to length, 14.000 inches nominal body length, 8.969 inches nominal body width, 4.531 inches nominal body height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
14.000 inches nominal
Body Width
8.969 inches nominal
Body Height
4.531 inches nominal
Center To Center Distance Between Terminals Parallel To Length
12.343 inches nominal
Center To Center Distance Between Terminals Parallel To Width
3.000 inches nominal
Unthreaded Mounting Hole Diameter
0.203 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
10.688 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches nominal
Fragility Factor
moderately rugged
End Item Identification
4920-01-070-2721
Boss Height
0.219 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
500.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
25000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
25.000 minimum at 300 pct and 200.000 maximum at 300 pct all locations
Inclosure Protection Type For Which Designed
general purpose
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
MA36500 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-181-2996?
The FSCG of the NSN 5925-01-181-2996 is 5925
Does the NSN 5925-01-181-2996 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-181-2996 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-181-2996 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-181-2996 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-181-2996 was assigned to the Federal Catalog?
It was assigned 42 years ago, on Fri, Jun 8, 1984

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

540-2757
7025-01-474-6126
Disk Drive Unit
540-2761
4140-01-480-3730
Tubeaxial Fan
540-277-100-790-600
5355-01-305-9045
Knob
540-277-260-777-000
5355-01-305-9044
Knob
540-277-260-777-001
5355-01-368-6808
Knob
540-2782-011
5998-01-475-5421
Circuit Card Assembly
540-2832-002
5305-00-559-9157
Externally Relieved Body Screw
540-2845-002
5360-00-510-4832
Pickup Rod Spring
540-2849-002
5821-00-009-1458
Spun Plate-Gear
540-287-320-777 -000
5305-01-431-8786
Hexagon Head Cap Screw
540-287-320-777-000
5340-01-418-7164
Access Cover
540-287-390-777
4810-01-434-3976
Valve Opening Indicator
540-287-390-777 -005
5355-01-305-9044
Knob
540-287-390-777-005
4810-01-434-3976
Valve Opening Indicator
540-2875
7025-01-476-1655
Disk Drive Unit