1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-173-1114

5925-01-173-1114

Find complete technical information, availability, and procurement data for: 5925-01-173-1114

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-173-1114 to receive an up to date pricing and availability quote by email.

5925-01-173-1114
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-173-1114
Item Name Code
00136
Assigment Date
02/29/1984 (42 years ago)

11.000 inches maximum body length, 9.000 inches maximum body width, multipole-single actuator type body style, 3.000 inches nominal center to center distance between terminals parallel to width, 9.875 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
11.000 inches maximum
Body Width
9.000 inches maximum
Center To Center Distance Between Terminals Parallel To Length
9.875 inches nominal
Center To Center Distance Between Terminals Parallel To Width
3.000 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.875 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches nominal
Boss Height
0.250 inches nominal
Mounting Surface To Terminal End Distance
9.312 inches maximum
Pole Quantity
3
Mounting Facility Type And Quantity
4 threaded hole
Storage Type
general purpose warehouse
Features Provided
adjustable trip release
Thread Quantity Per Inch
20
Maximum Continuous Load Current Rating Per Pole
125.0 amperes ac and 125.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac and 15000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Adjustable Trip Setting Current Range Per Pole In Amps
+650.0 to 1300.0 ac and +650.0 to 1300.0 dc all locations
Nominal Thread Size
0.250 inches
Inclosure Protection Type For Which Designed
general purpose
Trip Release Ambient Temp Rating
50.0 celsius nominal all locations
Frequency In Hertz
400.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
313C682G18 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-173-1114?
The FSCG of the NSN 5925-01-173-1114 is 5925
Does the NSN 5925-01-173-1114 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-173-1114 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-173-1114 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-173-1114 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-173-1114 was assigned to the Federal Catalog?
It was assigned 42 years ago, on Wed, Feb 29, 1984

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

2017299-0501
5915-00-974-3646
Electronic Phase Shifter
2017299-0503
5840-00-974-3681
Phase Shifter Assem
20173
2910-01-434-4428
Electrical Fuel Pump
20173-400
4730-01-202-4582
Manifold Subassembly
201730
5305-01-561-4135
Socket Head Cap Screw
2017307-39
5905-00-985-6238
Resistor,variable,wire Wound,non
2017308PC4
5910-00-985-2427
Paper Dielectric Fixed Capacitor
201731
4820-01-151-3260
Flow Control Valve
2017313-2
5940-00-682-9080
Stud Terminal
201731932
1560-01-665-4021
Aircraft Skin
201731932-10
1560-01-665-4021
Aircraft Skin
201731944
1680-01-665-6342
Overhaul Kit
201731945
1680-01-668-7452
Mecha Seal Replacement Parts Kit
201731946COVER
5930-01-667-4654
Electrical Switch Cover
201731PC6
5930-00-636-0696
Rotary Switch