Find complete technical information, availability, and procurement data for: 5925-01-149-9352

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-149-9352 to receive an up to date pricing and availability quote by email.

5925-01-149-9352
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-149-9352
Item Name Code
00136
Assigment Date
03/28/1983 (43 years ago)

single pole type body style, 0.450 inches nominal overall width, 0.137 inches nominal unthreaded mounting hole diameter, 1.970 inches nominal distance between centerlines of mounting facilities parallel to body length, 2.280 inches nominal overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Overall Length
2.280 inches nominal
Overall Width
0.450 inches nominal
Unthreaded Mounting Hole Diameter
0.137 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.970 inches nominal
Switch Contact Arrangement
single pole, double throw
Boss Height
0.177 inches nominal
Mounting Surface To Terminal End Distance
2.110 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
2 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac and 5.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 65.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
200.0 ac and 200.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal-magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push button
Actuator Function
trip w/separate reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
general purpose
Trip Release Ambient Temp Rating
70.0 fahrenheit nominal single location
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
1.0 ac and 1.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 65.0 dc
Unpackaged Unit Weight
1.160 ounces nominal
Frequency In Hertz
400.0 single location
Material
plastic case
Terminal Type And Quantity
2 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
43-500-L-SI,5AMP Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-149-9352?
The FSCG of the NSN 5925-01-149-9352 is 5925
Does the NSN 5925-01-149-9352 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-149-9352 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-149-9352 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-149-9352 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-149-9352 was assigned to the Federal Catalog?
It was assigned 43 years ago, on Mon, Mar 28, 1983

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

14542A
5330-00-877-5185
Blade Seal
14542ADX
3950-00-504-6240
Pulley Hous Support
14543
1560-00-036-6445
Aircraft Skin
14543-005
6210-01-161-6438
Light Lens
14543-010
5977-01-382-9412
Electrical Contact Ring Assembly
145430
4030-01-714-4731
Swivel and Link Assembly
1454300
6625-01-664-0608
Pulse Oximeter Simulator
14543001103
4820-01-415-4075
Valve Stem Guide
14543001156
4820-01-381-3867
Valve Stem Guide
145431
6240-00-014-5431
Incandescent Lamp
145431-05
5330-00-916-6339
Gasket
1454317
4320-01-336-6826
Pump Fluid Connector
145431Y2
3110-00-587-5587
Connecting Bearing
145433
4730-00-084-1920
Lubrication Fitting
145434
4730-00-460-3869
Lubrication Fitting