DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-143-5055 to receive an up to date pricing and availability quote by email.

5925-01-143-5055
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-143-5055
Item Name Code
00136
Assigment Date
12/05/1982 (43 years ago)

1.938 inches nominal center to center distance between terminals parallel to length, 2.500 inches nominal body length, 2.062 inches nominal distance between centerlines of mounting facilities parallel to body length, single pole type body style, 0.750 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.140 inches nominal
Mounting Surface To Terminal End Distance
2.409 inches minimum and 2.533 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.300 minimum at 200 pct and 1.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Unpackaged Unit Weight
0.312 pounds nominal
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
70-378-23-MG6 Circuit Breaker
G396183AE2R0A50 Circuit Breaker
G396183AE2ROA50 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-143-5055?
The FSCG of the NSN 5925-01-143-5055 is 5925
Does the NSN 5925-01-143-5055 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-143-5055 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-143-5055 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-143-5055 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-143-5055 was assigned to the Federal Catalog?
It was assigned 43 years ago, on Sun, Dec 5, 1982

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

GLS2104
4010-00-933-6396
Wire Rope
GLS25-101-0000
4510-01-714-6633
Single Faucet
GLS25/S1 20CC
5330-01-436-8771
Mecha Seal Replacement Parts Kit
GLS28
4130-01-130-5853
Glass Sight
GLS29
6680-00-302-1417
Liquid Sight Indicator
GLS29EE010-70-4I-NHE
5962-01-670-8791
Digital Microcircuit
GLS29EE512-70-4I-NHE
5962-01-682-1116
Microcircuit Assembly
GLS3
9340-00-111-0212
Observation Window
GLS30
4130-00-839-2464
Sight Glass
GLS34
9340-00-891-3003
Observation Window
GLS4
4310-00-632-2578
Sight Glass
GLS41A
4310-01-111-6863
Spacer Cylinder Window
GLS450
6685-01-695-2874
Dial Indicating Pressure Gage
GLS462
5120-01-277-2565
Socket Wrench Socket
GLS6A
4130-01-131-3971
Glass