DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-126-2383 to receive an up to date pricing and availability quote by email.

5925-01-126-2383
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-126-2383
Item Name Code
00136
Assigment Date
02/07/1982 (44 years ago)

2.000 inches nominal body length, 0.750 inches nominal center to center distance between terminals parallel to width, multipole-single actuator type body style, 2.250 inches nominal body width, 1.530 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
2.000 inches nominal
Body Width
2.250 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Boss Height
0.130 inches nominal
Mounting Surface To Terminal End Distance
2.032 inches maximum
Pole Quantity
3
Mounting Facility Type And Quantity
6 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2100.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 1.900 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
moisture resistant
Frequency In Hertz
400.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
APG-666-1-41-502 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-126-2383?
The FSCG of the NSN 5925-01-126-2383 is 5925
Does the NSN 5925-01-126-2383 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-126-2383 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-126-2383 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-126-2383 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-126-2383 was assigned to the Federal Catalog?
It was assigned 44 years ago, on Sun, Feb 7, 1982

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

140-1175
2940-01-044-0847
Intake Air Cleaner
140-119
5305-01-546-2588
Machine Screw
140-1194
2940-01-209-2143
Air Cleaner Cover
140-11KOHMSPORM0.025PCT
5905-01-064-9024
Wire Wound Fixed Resistor
140-12
4720-01-192-8096
Nonmetallic Hose Assembly
140-12-3
5940-00-204-8048
Stud Terminal
140-12-4MF
4730-00-489-8211
Tube Tee
140-120
5305-01-546-6459
Machine Screw
140-120-41
5905-00-106-3667
Composition Fixed Resistor
140-120-601
6030-01-431-4484
Fiber Optic Modem
140-1203
5910-01-042-1775
Paper Dielectric Fixed Capacitor
140-1204
2940-00-192-9182
Intake Air Cleane Filter Element
140-121
5340-01-548-6929
Rock Guard
140-1212
4730-01-077-0907
Pipe Coupling
140.121415
4330-01-534-3027
Fluid Filter Element