AM1-C3-30-2

View detailed technical data, stock status, and sourcing information for: AM1-C3-30-2

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part AM1-C3-30-2 to receive an up to date pricing and availability quote by email.

AM1-C3-30-2
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-111-9950
Item Name Code
00136
Assigment Date
04/24/1981 (45 years ago)

single pole type body style, 0.740 inches minimum and 0.760 inches maximum body width, 2.052 inches minimum and 2.072 inches maximum distance between centerlines of mounting facilities parallel to body length, 2.490 inches minimum and 2.510 inches maximum body length, 1.928 inches minimum and 1.948 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.490 inches minimum and 2.510 inches maximum
Body Width
0.740 inches minimum and 0.760 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.130 inches minimum and 0.150 inches maximum
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Ultimate Trip Time Per Pole In Seconds
10.000 minimum single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct and 0.400 minimum at 400 pct and 3.000 maximum at 400 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AM1-C3-30-2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-111-9950?
The FSCG of the NSN 5925-01-111-9950 is 5925
Does the NSN 5925-01-111-9950 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-111-9950 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-111-9950 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-111-9950 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-111-9950 was assigned to the Federal Catalog?
It was assigned 45 years ago, on Fri, Apr 24, 1981

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

206068-DI016
5975-01-298-3351
Flexible Conduit Assembly
206068A
5330-00-298-5935
Gasket
206069
3040-01-417-6800
Upper Guide
20606A
2040-01-667-7788
Plunger Index
20606L11-238
5930-01-154-0550
Thermostatic Switch
20607
1660-00-942-8452
Mask Button
20607-002
5930-01-325-0598
Electrical Switch
20607-501
5995-01-131-4922
E Special Purpose Cable Assembly
20607-502
5995-01-129-9182
E Special Purpose Cable Assembly
206070-1
5935-01-024-7684
Electrical Connector Cable Clamp
206070-8
5935-01-024-7684
Electrical Connector Cable Clamp
20607026
3020-01-287-4447
Spur Gear
20607027
3020-01-287-0826
Spur Gear
206070475-5
1660-01-121-0606
Aircraft Heating an Air Diffuser
2060706
5999-00-538-4342
Delay Line