5925-01-107-6622

Find complete technical information, availability, and procurement data for: 5925-01-107-6622

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-107-6622 to receive an up to date pricing and availability quote by email.

5925-01-107-6622
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-107-6622
Item Name Code
00136
Assigment Date
02/11/1981 (45 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

1.529 inches minimum and 1.591 inches maximum center to center distance between terminals parallel to length, multipole-multiple actuator type body style, 0.099 inches minimum and 0.161 inches maximum bushing length, 1.969 inches minimum and 2.031 inches maximum body width, 2.219 inches minimum and 2.281 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Bushing Length
0.099 inches minimum and 0.161 inches maximum
Body Length
2.219 inches minimum and 2.281 inches maximum
Body Width
1.969 inches minimum and 2.031 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.529 inches minimum and 1.591 inches maximum
Center To Center Distance Between Terminals Parallel To Width
1.629 inches minimum and 1.691 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.719 inches minimum and 0.781 inches maximum
Switch Contact Arrangement
single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.629 inches minimum and 1.691 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.032 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
6 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
2.100 minimum at 200 pct and 20.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
5.0 ac and 5.0 dc
Switch Voltage Rating And Type In Volts
240.0 ac and 50.0 dc
Frequency In Hertz
400.0 all locations
Material
plastic case
Test Data Document
"81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc
Terminal Type And Quantity
6 tab w/screw
Specification/Standard Data
81349-mil-c-55629/12 government specification

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
M55629/12-117 Circuit Breaker
MIL-C-55629/12 Circuit Breaker
MIL-PRF-55629/12 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-107-6622?
The FSCG of the NSN 5925-01-107-6622 is 5925
Does the NSN 5925-01-107-6622 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-107-6622 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-107-6622 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-107-6622 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-107-6622 was assigned to the Federal Catalog?
It was assigned 45 years ago, on Wed, Feb 11, 1981

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

9L6673
5330-01-318-4591
Gasket
9L6692
5340-01-148-8164
Cylinder Block Clip
9L67
5360-01-556-0850
Compression Helical Spring
9L672
4820-01-150-0965
Valve Disk
9L6743
2910-01-023-7504
Gover Control Group
9L6745
6685-01-071-7016
Flow Control Thermostat
9L6756
6620-01-018-9488
Thermostat Regulator
9L676
4820-00-436-1453
Check V Seat and Poppet Assembly
9L6770
3895-01-278-1610
Cap
9L6772
5935-01-098-8577
Electrical Plug Connector
9L6776
6130-01-476-0325
Metallic Rectifier Assembly
9L6782
5310-01-164-1650
Recessed Washer
9L6783
3040-01-278-1866
Shaft Collar
9L6807
3040-01-024-1001
Straight Shaft
9L6863
2910-01-147-3000
Fuel Pump Housing