1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-067-2927

5925-01-067-2927

Find complete technical information, availability, and procurement data for: 5925-01-067-2927

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-067-2927 to receive an up to date pricing and availability quote by email.

5925-01-067-2927
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-067-2927
Item Name Code
00136
Assigment Date
10/28/1978 (47 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

0.750 inches maximum body width, 2.189 inches maximum body length, single pole type body style, 0.220 inches minimum and 0.280 inches maximum bushing length, 1.160 inches minimum and 1.220 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.220 inches minimum and 0.280 inches maximum
Body Length
2.189 inches maximum
Body Width
0.750 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.160 inches minimum and 1.220 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.796 inches minimum and 1.828 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.000 inches maximum
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac and 10.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
205.0 ac and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac and 6000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct and 55.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Unpackaged Unit Weight
0.250 pounds nominal
Frequency In Hertz
400.0 single location
Test Data Document
"81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc
Terminal Type And Quantity
2 tab w/screw
Specification/Standard Data
96906-ms25244 government standard

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-257-6847 No Name Available 07/01/1988
5925-00-279-3217 No Name Available 07/01/1980
5925-00-472-6376 No Name Available 12/01/1993
5925-00-502-9990 No Name Available 09/24/1996
5925-00-686-0293 No Name Available 07/01/1988
5925-00-802-7833 No Name Available 05/01/1986

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
104-210-102 Circuit Breaker
1710C Circuit Breaker
1710CB Circuit Breaker
5925PL0897942 Circuit Breaker
BACC18J-10 Circuit Breaker
BACC18J10A Circuit Breaker
C5809BMS2505-10 Circuit Breaker
MS25244-P-10 Circuit Breaker
MS25244-P10 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-067-2927?
The FSCG of the NSN 5925-01-067-2927 is 5925
Does the NSN 5925-01-067-2927 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-067-2927 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-067-2927 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-067-2927 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-067-2927 was assigned to the Federal Catalog?
It was assigned 47 years ago, on Sat, Oct 28, 1978

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

2791692
6150-01-230-0055
E Special Purpose Cable Assembly
2791692-1
6150-01-230-0055
E Special Purpose Cable Assembly
2791693
6150-01-229-9876
E Special Purpose Cable Assembly
2791693-1
6150-01-209-9557
E Special Purpose Cable Assembly
2791693-3
6150-01-229-9876
E Special Purpose Cable Assembly
27916A
2990-01-479-4606
Exhaust Muffler
27916ISSUE5
5977-01-085-2778
Electrical Contact Brush
27916T9
5999-01-472-4915
Electrical Contact
27917
4730-00-897-2460
Fluid Passage Bolt
27917-78T9
5999-01-727-1801
Electrical Contact
27917-T9
5999-01-146-6466
Electrical Contact
2791707
2940-01-428-1816
Fluid Filter Element
279173
5930-01-044-9267
Push Switch
279176-1-1
4920-01-137-2851
Pump Assembly Arbor Balancing
2791760
5325-01-437-5347
Retaining Ring