5925-01-067-2924
Find complete technical information, availability, and procurement data for: 5925-01-067-2924
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-067-2924 to receive an up to date pricing and availability quote by email.
An adapter with electrical contacts which provides facilities for joining two or more electrical connectors, whose design or function will not normally warrant their junction. It is not designed for permanent attachment to a cable, cord, coaxial line, or wire. The physical shape of an electrical connector should not be the determining factor of its name. Tee, angle, straight, and y-shaped adapters are all adapter, connector. Excludes:adapter, connector to lampbase; adapter, lampholder to connector; adapter (1), cable clamp to connector; and adapter, lampholder. For items designed as a mechanical connection between an electrical conduit and an electrical connector, see adapter (1), electrical conduit.
single pole type body style, 0.531 inches minimum and 0.593 inches maximum body width, 0.562 inches minimum and 0.624 inches maximum center to center distance between terminals parallel to length, 0.219 inches minimum and 0.281 inches maximum bushing length, 0.749 inches minimum and 0.780 inches maximum body length
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Body Style
- single pole type
- Bushing Length
- 0.219 inches minimum and 0.281 inches maximum
- Body Length
- 0.749 inches minimum and 0.780 inches maximum
- Body Width
- 0.531 inches minimum and 0.593 inches maximum
- Center To Center Distance Between Terminals Parallel To Length
- 0.562 inches minimum and 0.624 inches maximum
- Switch Contact Arrangement
- single pole, single throw, normally closed
- Fragility Factor
- moderately rugged
- Mounting Surface To Terminal End Distance
- 1.494 inches minimum and 1.525 inches maximum
- Pole Quantity
- 1
- Mounting Facility Type And Quantity
- 1 threaded bushing
- Storage Type
- general purpose warehouse
- Thread Quantity Per Inch
- 32
- Maximum Continuous Load Current Rating Per Pole
- 2.5 amperes ac and 2.5 amperes dc single location
- Operating Voltage Type And Rating Per Pole In Volts
- 115.0 ac and 28.0 dc single location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 100.0 ac and 100.0 dc single location
- Circuit Protection Type
- overcurrent single location
- Trip Release Method
- thermal single location
- Trip Release Characteristic
- time delay single location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 145.0 single location
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Manual Actuator Type And Quantity
- 1 push-pull
- Actuator Function
- trip-reset
- Actuator Position Designation
- at pole one
- Auxiliary Switch Function And Quantity
- 1 control
- Internal Trip Release Configuration
- series trip single location
- Nominal Thread Size
- 0.438 inches
- Switch Location And Position Designation
- external at pole one
- Trip Delay Time In Seconds Per Rated Continuous Current
- 2.000 minimum at 200 pct and 20.000 maximum at 200 pct single location
- Inclosure Protection Type For Which Designed
- corrosion resistant and moisture resistant
- Trip Release Ambient Temp Rating
- 25.0 celsius nominal single location
- Switch Terminal Type
- tab, solder lug
- Switch Current Rating And Type In Amps
- 2.5 ac and 2.5 dc
- Switch Voltage Rating And Type In Volts
- 115.0 ac and 28.0 dc
- Frequency In Hertz
- 400.0 single location
- Test Data Document
- "81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
- Thread Series Designator
- un
- Terminal Type And Quantity
- 2 screw
- Specification/Standard Data
- 96906-ms26574 government specification
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 7274-4-2 1/2 | Circuit Breaker |
| MS26574-2-1/2A | Circuit Breaker |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5925-01-067-2924?
Does the NSN 5925-01-067-2924 have a Schedule B code assigned?
Does NSN 5925-01-067-2924 require demilitarization?
Does NSN 5925-01-067-2924 contain precious materials?
Does NSN 5925-01-067-2924 contain hazardous materials?
When the NSN 5925-01-067-2924 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: