1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-049-9184

5925-01-049-9184

Find complete technical information, availability, and procurement data for: 5925-01-049-9184

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-049-9184 to receive an up to date pricing and availability quote by email.

5925-01-049-9184
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-049-9184
Item Name Code
00136
Assigment Date
10/30/1977 (48 years ago)

multipole-single actuator type body style, 0.380 inches maximum bushing length, 1.875 inches maximum body width, 1.500 inches maximum body length, +0.3503 to 0.3537 inches thread pitch diameters

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.3503 to 0.3537 inches
Body Style
multipole-single actuator type
Bushing Length
0.380 inches maximum
Body Length
1.500 inches maximum
Body Width
1.875 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.780 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac and 2.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac and 28.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 1000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.008 minimum at 200 pct and 0.025 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
hermetically sealed
Unpackaged Unit Weight
6.300 ounces nominal
Frequency In Hertz
400.0 all locations
Thread Series Designator
unef
Terminal Type And Quantity
6 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
7603451 Circuit Breaker
AP-MIL-112 Circuit Breaker
AP112-4049-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-049-9184?
The FSCG of the NSN 5925-01-049-9184 is 5925
Does the NSN 5925-01-049-9184 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-049-9184 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-049-9184 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-049-9184 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-049-9184 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Sun, Oct 30, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

10-206985-1
2925-00-867-5933
Idnition Plug
10-206G
3040-01-652-9989
Mechanical Drive Housing
10-206K5TN
2940-00-610-3280
Air Cleaner Element
10-207
5120-01-581-0285
Socket Wrench Socket
10-207027
5915-00-807-0203
Radio Frequency Interfere Filter
10-20705-730001-1562
4320-01-286-0254
Centrifugal Pump Unit
10-207069
5950-00-776-9256
Power Transformer
10-207072
2925-00-774-6797
Exciter Ignition Housing
10-20709-24001X-6821P
4320-01-681-0812
Centrifugal Pump Unit
10-207100-5
2990-00-974-7443
Heater Manifold
10-207113
2920-00-711-5829
Spark Plug
10-207114
4810-00-974-7605
Solenoid Valve
10-207119
5950-00-776-9252
Power Transformer
10-207155-11
6625-00-804-1574
Spark Gap
10-207177
5910-00-776-6259
Capacitor Assembly