Find complete technical information, availability, and procurement data for: 5925-01-048-7483

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-048-7483 to receive an up to date pricing and availability quote by email.

5925-01-048-7483
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-048-7483
Item Name Code
00136
Assigment Date
10/03/1977 (48 years ago)

1.562 inches maximum body length, multipole-single actuator type body style, 0.380 inches maximum bushing length, 1.281 inches maximum body width, 0.906 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.380 inches maximum
Body Length
1.562 inches maximum
Body Width
1.281 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
Mounting Surface To Terminal End Distance
1.828 inches maximum
Pole Quantity
2
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac and 2.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc second location
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
between pole one and two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current
9.000 maximum at 200 pct second location
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
Frequency In Hertz
400.0 all locations
Thread Series Designator
unef
Terminal Type And Quantity
4 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
472AS138 Circuit Breaker
AP12-3231-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-048-7483?
The FSCG of the NSN 5925-01-048-7483 is 5925
Does the NSN 5925-01-048-7483 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-048-7483 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-048-7483 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-048-7483 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-048-7483 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Mon, Oct 3, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

28R
6145-01-515-6185
Electrical Wire
28R-37-5800
5905-00-471-4592
Wire Wound Fixed Resistor
28R-T
6145-01-084-1510
Electrical Wire
28R0
5815-00-064-5592
Teleprinter
28R00-1
5120-01-428-3725
Automatic Center Punch
28R0039
5920-01-514-2793
Cartridge Fuse
28R10245
5945-01-357-5841
Electrical Solenoid
28R2083
5999-00-501-8369
Electrical Clip
28R26S20C
8115-01-337-8675
Shipping Box
28R2E215
5945-00-954-2409
Electromagnetic Relay
28R340-15
6130-01-247-3418
Power Supply
28R45-1
5120-01-428-3724
Automatic Center Punch
28R4S10C
8115-01-146-1126
Shipping Box
28R6-180-F64-B2
5340-00-917-4740
Bail Handle
28R7010-1L8.5
5995-00-174-8195
Radio Frequency Cable Assembly