DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-045-2119 to receive an up to date pricing and availability quote by email.

5925-01-045-2119
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-045-2119
Item Name Code
00136
Assigment Date
07/28/1977 (49 years ago)

An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), printed wiring board, or the like for convenience in joining with another electrical connector or printed wiring board. It is designed to be mounted on a bulkhead, chassis, panel, wall, printed wiring board, or the like. Excludes:lampholder; jack,telephone; jack,tip; insert electrical connector; insert module,electrical connector; connector body (as modified) and socket,plug-in electronic components. See also wiring harness (as modified) and cable assembly (as modified). For items with termination wires of more than four inches in length, see lead assembly,electrical. For items without inserts, see shell,electrical connector.

0.800 inches nominal center to center distance between terminals parallel to length, multipole-single actuator type body style, 2.000 inches maximum body length, 0.850 inches maximum body width, 0.250 inches nominal bushing length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.250 inches nominal
Body Length
2.000 inches maximum
Body Width
0.850 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.800 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.500 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.765 inches maximum
Pole Quantity
3
Arc Quenching Method
air
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
750.0 milliamperes ac and 750.0 milliamperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 28.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac and 2000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
nontrip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.469 inches
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct and 35.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal all locations
Frequency In Hertz
400.0 all locations
Thread Series Designator
uns
Terminal Type And Quantity
6 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
7276-101-3/4 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-045-2119?
The FSCG of the NSN 5925-01-045-2119 is 5925
Does the NSN 5925-01-045-2119 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-045-2119 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-045-2119 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-045-2119 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-045-2119 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Thu, Jul 28, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

M19646-C124D425
6685-01-281-4605
Capillary Indicating Thermometer
M19646-C124D430
6685-01-493-4710
Capillary Indicating Thermometer
M19646-C2-18D330
6685-01-022-8479
Capillary Indicating Thermometer
M19646-C212H415
6685-01-012-2597
Capillary Indicating Thermometer
M19646-C212H420
6685-01-091-5721
Capillary Indicating Thermometer
M19646-C212H830
6685-01-122-7470
Capillary Indicating Thermometer
M19646-C218D3120
6685-01-509-9460
Capillary Indicating Thermometer
M19646-C218D410
6685-01-120-5281
Capillary Indicating Thermometer
M19646-C218D4105
6685-01-509-9449
Capillary Indicating Thermometer
M19646-C218D420
6685-01-088-1667
Capillary Indicating Thermometer
M19646-C218D440
6685-01-488-9481
Capillary Indicating Thermometer
M19646-C218D445
6685-01-509-9455
Capillary Indicating Thermometer
M19646-C218D45
6685-01-089-9606
Capillary Indicating Thermometer
M19646-C218D470
6685-01-509-9450
Capillary Indicating Thermometer
M19646-C218D480
6685-01-509-9436
Capillary Indicating Thermometer