601A302SGL

View detailed technical data, stock status, and sourcing information for: 601A302SGL

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 601A302SGL to receive an up to date pricing and availability quote by email.

601A302SGL
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-036-6628
Item Name Code
00136
Assigment Date
02/26/1977 (49 years ago)

1.531 inches minimum and 1.562 inches maximum body length, 0.594 inches minimum and 0.625 inches maximum body width, single pole type body style, 0.332 inches minimum and 0.380 inches maximum bushing length, 0.875 inches minimum and 0.906 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.332 inches minimum and 0.380 inches maximum
Body Length
1.531 inches minimum and 1.562 inches maximum
Body Width
0.594 inches minimum and 0.625 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and 0.906 inches maximum
Mounting Surface To Terminal End Distance
1.669 inches minimum and 1.700 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac and 3.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and 50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac and 500.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct and 0.950 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
Frequency In Hertz
400.0 single location
Test Data Document
"81349-mil-prf-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unef
Terminal Type And Quantity
2 wire hook
Specification/Standard Data
81349-mil-prf-39019/1 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-626-4338 No Name Available 07/01/1992
5925-00-704-5734 No Name Available 04/01/2008
5925-00-880-8380 No Name Available 07/01/1984
5925-00-893-8642 No Name Available 08/22/2001

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
3200722-3 Circuit Breaker
353649-33 Circuit Breaker
601A302SGL Circuit Breaker
6207129 Circuit Breaker
7907115-06 Circuit Breaker
ES1843-4A302 Circuit Breaker
M39019-1-31 Circuit Breaker
M39019/01-224 Circuit Breaker
M39019/1-37 Circuit Breaker
MIL-PRF-39019/1G Circuit Breaker
SM3-3-115VAC400-58 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-036-6628?
The FSCG of the NSN 5925-01-036-6628 is 5925
Does the NSN 5925-01-036-6628 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-036-6628 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-036-6628 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-036-6628 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-036-6628 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Sat, Feb 26, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

43F6218MA6
5910-00-829-3082
Electrolytic Fixed Capacitor
43F6230CA6
5910-00-814-8647
Electrolytic Fixed Capacitor
43F6236MA3
5910-01-034-8023
Electrolytic Fixed Capacitor
43F6274MA3
5910-00-674-4796
Electrolytic Fixed Capacitor
43F6900MA4
5910-00-135-8445
Electrolytic Fixed Capacitor
43F7147AA1
5910-01-141-5336
Electrolytic Fixed Capacitor
43F747DA1
5910-00-648-8805
Electrolytic Fixed Capacitor
43F7534BA1
5910-00-854-7457
Electrolytic Fixed Capacitor
43F7573AA1
5910-01-040-1245
Electrolytic Fixed Capacitor
43F7600AA1
5905-00-781-3773
Resistor,fixed,wire Wound,induct
43F767DA1
5910-01-007-6351
Electrolytic Fixed Capacitor
43F7750
6130-01-416-8832
Power Supply
43F790CA3
5910-00-835-6653
Electrolytic Fixed Capacitor
43F791CA3
5910-00-835-6656
Electrolytic Fixed Capacitor
43F792CA3
5910-00-835-6655
Electrolytic Fixed Capacitor