1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-035-5643

5925-01-035-5643

Find complete technical information, availability, and procurement data for: 5925-01-035-5643

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-035-5643 to receive an up to date pricing and availability quote by email.

5925-01-035-5643
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-035-5643
Item Name Code
00136
Assigment Date
02/11/1977 (49 years ago)

multipole-single actuator type body style, 1.500 inches nominal body width, 2.000 inches nominal body height, 1.560 inches nominal center to center distance between terminals parallel to length, 2.000 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
2.000 inches nominal
Body Width
1.500 inches nominal
Body Height
2.000 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.560 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Boss Height
0.130 inches nominal
Pole Quantity
2
Mounting Facility Type And Quantity
4 threaded hole
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
116.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
2 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one and two linked
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 2.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
dustproof
Frequency In Hertz
400.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
4 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
78A0099-002 Circuit Breaker
UPGH11-3176-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-035-5643?
The FSCG of the NSN 5925-01-035-5643 is 5925
Does the NSN 5925-01-035-5643 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-035-5643 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-035-5643 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-035-5643 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-035-5643 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Fri, Feb 11, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

25UJ-06
4730-01-066-3071
Pipe Elbow
25UJ04
4730-01-295-6129
Tube Elbow
25UJ12
4730-00-288-9773
Pipe Elbow
25UKS332
6685-00-515-3481
Dial Indicating Pressure Gage
25ULA-1000DT
5910-00-590-6966
Electrolytic Fixed Capacitor
25ULA100
5910-01-074-8574
Electrolytic Fixed Capacitor
25ULA10T
5910-01-141-2640
Electrolytic Fixed Capacitor
25ULA10V-T
5910-01-123-9845
Electrolytic Fixed Capacitor
25ULA2200
5910-01-168-9836
Electrolytic Fixed Capacitor
25UM1001
3120-01-667-3653
Sleeve Bushing
25UM1007
3120-01-667-3677
Sleeve Bushing
25UM1011A
5975-01-642-4678
Cable Reinforcing Link
25UM1013
1560-01-647-9147
Air Structural Component Support
25UM1019
3120-01-667-3647
Sleeve Bushing
25UM1045-5
5306-01-648-4368
Shear Bolt