1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-013-7119

5925-01-013-7119

Find complete technical information, availability, and procurement data for: 5925-01-013-7119

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-013-7119 to receive an up to date pricing and availability quote by email.

5925-01-013-7119
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-013-7119
Item Name Code
00136
Assigment Date
12/07/1975 (50 years ago)

0.593 inches nominal center to center distance between terminals parallel to length, 0.562 inches nominal body width, 0.359 inches nominal bushing length, single pole type body style, 0.750 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.359 inches nominal
Body Length
0.750 inches nominal
Body Width
0.562 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.593 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.420 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac and 5.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac and 1000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.438 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 35.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
vibration resistant and humidity resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
uns
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
1802786-9 Circuit Breaker
769-2-261200 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-013-7119?
The FSCG of the NSN 5925-01-013-7119 is 5925
Does the NSN 5925-01-013-7119 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-013-7119 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-013-7119 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-013-7119 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-013-7119 was assigned to the Federal Catalog?
It was assigned 50 years ago, on Sun, Dec 7, 1975

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

G370-110
5307-00-298-2612
Plain Stud
G370001-1
5945-00-201-5144
Electromagnetic Relay
G370001-10
5945-00-201-5141
Electromagnetic Relay
G370001-11
5945-00-283-6339
Electromagnetic Relay
G370001-4
5945-00-201-5145
Electromagnetic Relay
G370001-5
5945-00-259-6399
Electromagnetic Relay
G370001-9
5945-00-201-5139
Electromagnetic Relay
G370005S1
5945-00-827-7203
Electromagnetic Relay
G370006S1
5945-00-542-7021
Thermal Relay
G370007S1
5945-00-827-7205
Electromagnetic Relay
G370009S1
5945-00-258-5061
Electromagnetic Relay
G370032S1
5945-00-089-2537
Electromagnetic Relay
G370032S2
5945-00-089-2490
Electromagnetic Relay
G370033S1
5945-00-808-6345
Electromagnetic Relay
G370035S1
5945-00-089-2531
Electromagnetic Relay