511-220-101

View detailed technical data, stock status, and sourcing information for: 511-220-101

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 511-220-101 to receive an up to date pricing and availability quote by email.

511-220-101
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-010-8922
Item Name Code
00136
Assigment Date
10/09/1975 (50 years ago)

0.750 inches nominal body width, 2.062 inches nominal distance between centerlines of mounting facilities parallel to body length, 1.560 inches nominal center to center distance between terminals parallel to length, single pole type body style, 2.000 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.000 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.560 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.130 inches nominal
Mounting Surface To Terminal End Distance
1.880 inches nominal
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
1.800 minimum at 200 pct and 10.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 quick disconnect, male

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
427-50-106176 Circuit Breaker
511-220-101 Circuit Breaker
62828-90037-5 Circuit Breaker
JA1S-D3-20-2 Circuit Breaker
UPG1-1-62-203-90 Circuit Breaker
W67-X2Q12-20 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-010-8922?
The FSCG of the NSN 5925-01-010-8922 is 5925
Does the NSN 5925-01-010-8922 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-010-8922 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-010-8922 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-010-8922 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-010-8922 was assigned to the Federal Catalog?
It was assigned 50 years ago, on Thu, Oct 9, 1975

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

2Z3082-286
5935-00-508-7097
Electrical Plug Connector
2Z3224-2
5975-00-497-0289
Electrical Conduit Coupling Nut
2Z3224-5
3040-00-554-7674
Flexible Casing End Fitting
2Z3265-92
5826-00-507-7864
Coupling Unit
2Z3269-11
3010-00-277-3839
Flexible Shaft Coupling
2Z3273-360
5985-00-508-7162
Radio Frequency Rotary Coupler
2Z3276
5826-00-568-7786
Coupling
2Z328
4330-01-056-3122
Fluid Filter
2Z329
4330-01-495-4256
Fluid Filter
2Z3295-147
3010-00-565-7359
Flexible Shaft Coupling
2Z329B
4330-01-495-4256
Fluid Filter
2Z330
4330-01-311-3384
Fluid Filter
2Z330A
4330-01-311-3384
Fluid Filter
2Z3351-36
5935-00-187-1619
Electrical Connector Cover
2Z3351-458
5821-00-041-1845
Plate