5925-01-007-9407

Find complete technical information, availability, and procurement data for: 5925-01-007-9407

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-007-9407 to receive an up to date pricing and availability quote by email.

5925-01-007-9407
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-007-9407
Item Name Code
00136
Assigment Date
08/15/1975 (50 years ago)

An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes:a single inductance, or a single capacitance, or a single resistance. See coil (as modified); reactor; capacitor (as modified); and resistor (as modified).

0.250 inches nominal bushing length, 1.313 inches minimum and 1.375 inches maximum body length, single pole type body style, 0.906 inches nominal center to center distance between terminals parallel to length, 0.688 inches minimum and 0.750 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.250 inches nominal
Body Length
1.313 inches minimum and 1.375 inches maximum
Body Width
0.688 inches minimum and 0.750 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
Mounting Surface To Terminal End Distance
1.250 inches minimum and 1.312 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac and 20.0 amperes dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac and 4000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Ultimate Trip Time Per Pole In Seconds
60.000 nominal single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Internal Trip Release Configuration
series trip w/auxiliary load terminal and remote trip feature single location
Nominal Thread Size
0.138 inches
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Material
plastic case
Thread Series Designator
unf
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
382-2074-2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-007-9407?
The FSCG of the NSN 5925-01-007-9407 is 5925
Does the NSN 5925-01-007-9407 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-007-9407 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-007-9407 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-007-9407 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-007-9407 was assigned to the Federal Catalog?
It was assigned 50 years ago, on Fri, Aug 15, 1975

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

784899-11
1560-00-863-2875
Fuel Tan Panel Assy
7848K1
5930-01-414-8225
Rotary Switch
7848K2
5930-00-784-8989
Rotary Switch
7848R-25
3110-00-554-5403
Annular Ball Bearing
7848R-35
3110-00-516-5490
Annular Ball Bearing
7848T1
8010-01-498-5057
Heat Resisting Paint
7848T4
8010-01-498-5057
Heat Resisting Paint
7848W
5310-01-615-6057
Hexagon Plain Nut
7849
5950-00-877-6225
Power Transformer
7849-4-SS316
4820-01-697-2518
Valve Tailpiece
7849-8-20
5925-01-454-7306
Circuit Breaker
78490
2990-01-295-6028
Exhaust Muffler
784900
4810-01-185-4208
Relief Va Cartridge
7849002P001
5962-01-280-1453
Digital Microcircuit
7849090
2520-00-722-7074
Universal Joint Parts Kit