1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-960-5214

5925-00-960-5214

Find complete technical information, availability, and procurement data for: 5925-00-960-5214

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-960-5214 to receive an up to date pricing and availability quote by email.

5925-00-960-5214
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-960-5214
Item Name Code
00136
Assigment Date
05/25/1966 (60 years ago)

0.750 inches maximum body width, 0.240 inches minimum and 0.260 inches maximum bushing length, 1.094 inches maximum body length, single pole type body style, 0.693 inches minimum and 0.713 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.240 inches minimum and 0.260 inches maximum
Body Length
1.094 inches maximum
Body Width
0.750 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.693 inches minimum and 0.713 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.812 inches maximum
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac and 5.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
6000.0 ac and 6000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push button
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.469 inches
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 minimum at 200 pct and 55.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
explosion proof
Unpackaged Unit Weight
0.093 pounds nominal
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
uns
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
467740-8 Circuit Breaker
700-020-5 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-960-5214?
The FSCG of the NSN 5925-00-960-5214 is 5925
Does the NSN 5925-00-960-5214 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-960-5214 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-960-5214 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-960-5214 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-960-5214 was assigned to the Federal Catalog?
It was assigned 60 years ago, on Wed, May 25, 1966

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

USGS 24K70395
7643-01-640-5147
Topographic Geospatial Products
USGS 24K70396
7643-01-640-0812
Topographic Geospatial Products
USGS 24K70397
7643-01-635-6578
Topographic Geospatial Products
USGS 24K70398
7643-01-638-5235
Topographic Geospatial Products
USGS 24K70399
7643-01-637-5101
Topographic Geospatial Products
USGS 24K704
7643-01-639-4823
Topographic Geospatial Products
USGS 24K7040
7643-01-638-4731
Topographic Geospatial Products
USGS 24K70400
7643-01-639-0023
Topographic Geospatial Products
USGS 24K70401
7643-01-636-1666
Topographic Geospatial Products
USGS 24K70402
7643-01-636-7140
Topographic Geospatial Products
USGS 24K70403
7643-01-637-2614
Topographic Geospatial Products
USGS 24K70404
7643-01-636-2225
Topographic Geospatial Products
USGS 24K70405
7643-01-636-2819
Topographic Geospatial Products
USGS 24K70406
7643-01-635-6592
Topographic Geospatial Products
USGS 24K70407
7643-01-638-8615
Topographic Geospatial Products