SM-D-601110-2

View detailed technical data, stock status, and sourcing information for: SM-D-601110-2

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part SM-D-601110-2 to receive an up to date pricing and availability quote by email.

SM-D-601110-2
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-937-9572
Item Name Code
00136
Assigment Date
02/15/1967 (59 years ago)

1.250 inches maximum body width, 1.500 inches maximum body length, 0.375 inches nominal bushing length, 0.875 inches nominal center to center distance between terminals parallel to length, multipole-single actuator type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.375 inches nominal
Body Length
1.500 inches maximum
Body Width
1.250 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.780 inches maximum
Pole Quantity
2
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
12.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
between pole one and two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 minimum at 200 pct and 0.550 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
dustproof
Thread Series Designator
unef
Terminal Type And Quantity
4 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AP12-1388-2 Circuit Breaker
HM2-M3-12-A Circuit Breaker
SM-D-601110-2 Circuit Breaker
SM33-12-50VDC2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-937-9572?
The FSCG of the NSN 5925-00-937-9572 is 5925
Does the NSN 5925-00-937-9572 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-937-9572 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-937-9572 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-937-9572 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-937-9572 was assigned to the Federal Catalog?
It was assigned 59 years ago, on Wed, Feb 15, 1967

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

M41CO 51
5133-01-095-4781
Twist Drill
M41CO 52
5133-01-095-4782
Twist Drill
M41CO 53
5133-01-220-6228
Twist Drill
M41CO 54
5133-01-341-3805
Twist Drill
M41CO 55
5133-01-220-6223
Twist Drill
M41CO 56
5133-01-220-6224
Twist Drill
M41CO 57
5133-01-220-6222
Twist Drill
M41CO 59
5133-01-220-6226
Twist Drill
M41CO 6
5133-01-095-4744
Twist Drill
M41CO 60
5133-01-220-6227
Twist Drill
M41CO 7
5133-01-095-4745
Twist Drill
M41CO 9
5133-01-095-4746
Twist Drill
M41DGFX7
3540-01-709-2188
Sealing Machine
M41F
5950-01-122-1579
Power Transformer
M41PFSL
5935-00-880-2791
Electrical Receptacle Connector