1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-924-9596

5925-00-924-9596

Find complete technical information, availability, and procurement data for: 5925-00-924-9596

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-924-9596 to receive an up to date pricing and availability quote by email.

5925-00-924-9596
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-924-9596
Item Name Code
00136
Assigment Date
01/24/1966 (60 years ago)

single pole type body style, 3.050 inches minimum and 3.070 inches maximum center to center distance between terminals parallel to length, 3.667 inches minimum and 3.793 inches maximum body length, 0.937 inches minimum and 1.063 inches maximum body width, 2.740 inches minimum and 2.760 inches maximum distance between centerlines of mounting facilities parallel to body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
3.667 inches minimum and 3.793 inches maximum
Body Width
0.937 inches minimum and 1.063 inches maximum
Center To Center Distance Between Terminals Parallel To Length
3.050 inches minimum and 3.070 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.097 inches minimum and 0.223 inches maximum
Mounting Surface To Terminal End Distance
2.960 inches minimum and 3.150 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
100.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
10.500 minimum at 200 pct and 50.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
vibration resistant and shock resistant and salt spray proof and humidity resistant
Unpackaged Unit Weight
0.530 pounds nominal
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
260-4032-010 Circuit Breaker
50-152-1MG3 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-924-9596?
The FSCG of the NSN 5925-00-924-9596 is 5925
Does the NSN 5925-00-924-9596 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-924-9596 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-924-9596 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-924-9596 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-924-9596 was assigned to the Federal Catalog?
It was assigned 60 years ago, on Mon, Jan 24, 1966

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

BACU24AA0806D
4730-01-328-0941
Tube Reducer
BACU24AA0806K
4710-01-480-6357
Metallic Tube
BACU24AA0806T
4730-01-523-5649
Tube Reducer
BACU24AA0810J
4730-01-386-3096
Pipe Union
BACU24AA1604T
4730-01-523-8727
Tube Union
BACU24AB16AW
4730-01-523-8728
Tube Union
BACU24AB20W
4730-01-523-8717
Tube Union
BACU24AB6H
4730-01-630-3510
Tube Union
BACU24AB6W
4730-01-714-2460
Tube Union
BACU24AB8W
4730-01-523-8713
Tube Union
BACU24AB8WL
4730-01-241-0325
Tube Union
BACU24AR12-10
4730-01-048-3493
Tube Reducer
BACU24AW16JL
4820-01-347-8530
Valve Seat
BACU24AZ0106J
4730-00-897-5337
Tube Reducer
BACU24AZ06D
4730-01-654-7196
Tube Union