SMC602991

View detailed technical data, stock status, and sourcing information for: SMC602991

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part SMC602991 to receive an up to date pricing and availability quote by email.

SMC602991
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-924-9578
Item Name Code
00136
Assigment Date
01/24/1966 (60 years ago)

2.062 inches nominal distance between centerlines of mounting facilities parallel to body length, 2.500 inches nominal body length, single pole type body style, 0.750 inches nominal body width, 1.938 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.140 inches nominal
Mounting Surface To Terminal End Distance
2.611 inches nominal
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct and 10.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-852-1849 No Name Available 06/13/1973

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
122-230-101 Circuit Breaker
632238-206 Circuit Breaker
63A109B156 Circuit Breaker
70-868MG3-206 Circuit Breaker
AM12MG6-30-250-4-60 Circuit Breaker
AM12MG6-30-250VAC60C4 Circuit Breaker
SMC602991 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-924-9578?
The FSCG of the NSN 5925-00-924-9578 is 5925
Does the NSN 5925-00-924-9578 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-924-9578 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-924-9578 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-924-9578 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-924-9578 was assigned to the Federal Catalog?
It was assigned 60 years ago, on Mon, Jan 24, 1966

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

3998281
2805-01-193-2777
Engine Flywheel
3998287
3040-00-949-1631
Oil Pump Drive Shaft
3998289
3040-00-949-1631
Oil Pump Drive Shaft
399829
5330-01-304-7862
Packing Retainer
39982E
4820-01-284-7444
Valve Diaphram Retainer
39983
4820-01-145-5601
Valve Disk
39983-4
5820-00-945-8020
Module
399832-1
5962-00-492-0147
Digital Microcircuit
3998333
2805-00-778-0126
Gasoline Engine
399833PC4
5950-00-339-4273
Power Transformer
399833PC49
5950-00-339-4273
Power Transformer
399834
2915-00-738-9007
Flowmeter Adapter
399835
4320-01-187-6479
Centrifugal Pump Unit
399836
5360-01-294-8658
Compression Helical Spring
399836-1
1560-00-421-5680
Aircraft Structural Panel