DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-902-0306 to receive an up to date pricing and availability quote by email.

5925-00-902-0306
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-902-0306
Item Name Code
00136
Assigment Date
02/08/1967 (59 years ago)

2.750 inches nominal distance between centerlines of mounting facilities parallel to body length, 0.990 inches nominal body width, 3.719 inches nominal body length, single pole type body style, 3.063 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
3.719 inches nominal
Body Width
0.990 inches nominal
Center To Center Distance Between Terminals Parallel To Length
3.063 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.156 inches nominal
Mounting Surface To Terminal End Distance
3.177 inches minimum and 3.301 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
fragile
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
50.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
4000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct and 100.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Unpackaged Unit Weight
0.690 pounds nominal
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
50-167-5 Circuit Breaker
50-167-5-MG3 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-902-0306?
The FSCG of the NSN 5925-00-902-0306 is 5925
Does the NSN 5925-00-902-0306 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-902-0306 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-902-0306 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-902-0306 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-902-0306 was assigned to the Federal Catalog?
It was assigned 59 years ago, on Wed, Feb 8, 1967

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

G629X2251
7643-01-562-9129
Topographic Geospatial Products
G62B
5999-00-879-1521
Connector-Switch
G62B6D
5985-01-591-5705
Waveguide Seal
G62D01SHIP
5925-01-674-4116
Circuit Breaker
G62D06SHIP
5925-01-674-7499
Circuit Breaker
G62M
5996-01-441-6740
Audio Frequency Amplifier
G62PTMW0DV08400
6685-01-272-3137
Dial Indicating Pressure Gage
G63
4930-01-443-9635
Lubricant Transfer Pump
G63-0031-PC
4720-01-559-1721
Nonmetallic Hose Assembly
G63-1
4730-00-879-3582
Lubrication Fitting
G63-12-2
5340-01-629-1785
Loop Clamp
G63-12-3
5340-01-629-1785
Loop Clamp
G63-1325
1680-01-479-7377
Spring
G63-2
4730-01-341-7587
Lubrication Fitting
G63-2PC1T015-37
6105-00-506-2265
Motor Armature