DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-883-6936 to receive an up to date pricing and availability quote by email.

5925-00-883-6936
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-883-6936
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

2.500 inches nominal body length, 1.812 inches nominal distance between centerlines of mounting facilities parallel to body length, 1.190 inches nominal center to center distance between terminals parallel to length, single pole type body style, 0.750 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.000 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 nominal at 200 pct and 0.050 nominal at 300 pct single location
Inclosure Protection Type For Which Designed
explosion resistant
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
335C757H22 Circuit Breaker
AM17-5-120-208 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-883-6936?
The FSCG of the NSN 5925-00-883-6936 is 5925
Does the NSN 5925-00-883-6936 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-883-6936 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-883-6936 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-883-6936 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-883-6936 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

0N271605
5998-01-155-5482
Circuit Card Assembly
0N271621
5950-01-145-5845
Reactor
0N271771
5998-01-126-2238
Circuit Card Assembly
0N271830
5995-01-138-8358
E Special Purpose Cable Assembly
0N271833
5950-01-138-8216
Reactor Assembly
0N271841-1
5935-01-157-1940
Electrical Connector Cover
0N271900-1
5305-01-272-8690
Machine Screw
0N271901-1
5962-01-139-4764
Digital Microcircuit
0N271901-2
5962-01-273-8860
Digital Microcircuit
0N271902
5310-01-271-1407
Hexagon Self-Locking Nut
0N271903-1
5930-01-144-9951
Push Switch
0N271903-10
5930-01-144-9960
Push Switch
0N271903-12
5930-01-144-9961
Push Switch
0N271903-13
5930-01-144-9962
Push Switch
0N271903-14
5999-01-144-9944
Electronic Components Housing