1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-781-4535

5925-00-781-4535

Find complete technical information, availability, and procurement data for: 5925-00-781-4535

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-781-4535 to receive an up to date pricing and availability quote by email.

5925-00-781-4535
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-781-4535
Item Name Code
00136
Assigment Date
01/01/1960 (66 years ago)

2.485 inches minimum and 2.515 inches maximum body length, 2.230 inches minimum and 2.270 inches maximum body width, 1.925 inches minimum and 1.955 inches maximum center to center distance between terminals parallel to length, multipole-multiple actuator type body style, 0.735 inches minimum and 0.765 inches maximum center to center distance between terminals parallel to width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
2.485 inches minimum and 2.515 inches maximum
Body Width
2.230 inches minimum and 2.270 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.925 inches minimum and 1.955 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.047 inches minimum and 2.077 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.125 inches minimum and 0.155 inches maximum
Mounting Surface To Terminal End Distance
2.475 inches minimum and 2.505 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
6 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 10.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
salt spray proof and shock resistant and vibration resistant and moisture resistant
Unpackaged Unit Weight
0.875 pounds nominal
Frequency In Hertz
400.0 all locations
Material
plastic case
Test Data Document
05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
unc
Terminal Type And Quantity
6 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
711570-154 Circuit Breaker
72-126-11MG6 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-781-4535?
The FSCG of the NSN 5925-00-781-4535 is 5925
Does the NSN 5925-00-781-4535 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-781-4535 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-781-4535 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-781-4535 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-781-4535 was assigned to the Federal Catalog?
It was assigned 66 years ago, on Fri, Jan 1, 1960

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

A3080491-1
5895-01-326-0663
Power Monitor
A3080491-2
5895-01-326-0664
Local Power Sensor
A3080491-3
5995-01-325-9909
Radio Frequency Cable Assembly
A3080491-4
5995-01-326-5315
Radio Frequency Cable Assembly
A3080491-5
5895-01-326-0665
Remote Power Sensor
A3080491-6
5995-01-325-6787
Radio Frequency Cable Assembly
A3080491-7
5998-01-309-9082
Circuit Card Assembly
A3080491-8
5998-01-309-9081
Circuit Card Assembly
A3080491-9
5998-01-309-6794
Circuit Card Assembly
A30805
6740-01-486-0837
Photographic Processing Machine
A3080504-1
5985-01-407-7639
Variable Attenuator
A3080560-1
5895-01-284-8306
Communications Term
A3080560-2
5895-01-284-8307
Communications Term
A3080560-4
5895-01-463-4064
Satellite Communication Terminal
A3080560-5
5895-01-522-9993
Satellite Communication Terminal