DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-755-2995 to receive an up to date pricing and availability quote by email.

5925-00-755-2995
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-755-2995
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

0.375 inches nominal bushing length, 0.598 inches nominal body width, 0.875 inches nominal center to center distance between terminals parallel to length, single pole type body style, 1.479 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.375 inches nominal
Body Length
1.479 inches nominal
Body Width
0.598 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.555 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.800 minimum at 200 pct and 4.500 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and explosion resistant and hermetically sealed
Unpackaged Unit Weight
2.100 ounces nominal
Frequency In Hertz
60.0 single location
Thread Series Designator
unef
Terminal Type And Quantity
2 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
10351688 Circuit Breaker
HE1-A3-3-1 Circuit Breaker
HE1-A3-3-120-1-60 Circuit Breaker
HE1-A3-3-120FC-1-60HZ Circuit Breaker
SM3-3 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-755-2995?
The FSCG of the NSN 5925-00-755-2995 is 5925
Does the NSN 5925-00-755-2995 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-755-2995 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-755-2995 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-755-2995 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-755-2995 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

3472713
5935-01-199-2826
Electrical Connector Bracket
347273-001
5998-01-024-2089
Circuit Card Assembly
347273-KITA
4820-01-305-0079
Valve Parts Kit
347274R1
2520-00-905-4208
Backup Ring
347275
1650-00-104-8277
Hydraulic Motor
347275-KITA
3040-01-305-2162
Gearbox Parts Kit
347276-1
5340-01-104-5267
Dust and Moi Protective Cap-Plug
3472764-2
5999-01-096-0209
Electrical Contact
3472764-3
5999-01-096-0210
Electrical Contact
347276R1
5330-00-927-7944
Preformed Packing
347277-001
5998-01-025-3618
Circuit Card Assembly
3472775
5342-01-093-6529
Desiccant Cover
347278-001
5998-01-025-3615
Circuit Card Assembly
347278R1
5330-00-973-8272
Preformed Packing
34728
4720-01-285-4989
Metallic Hose Assembly