1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-752-4110

5925-00-752-4110

Find complete technical information, availability, and procurement data for: 5925-00-752-4110

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-752-4110 to receive an up to date pricing and availability quote by email.

5925-00-752-4110
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-752-4110
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

1.928 inches minimum and 1.948 inches maximum center to center distance between terminals parallel to length, 2.490 inches minimum and 2.510 inches maximum body width, 2.500 inches nominal body length, 2.052 inches minimum and 2.072 inches maximum distance between centerlines of mounting facilities parallel to body length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
2.490 inches minimum and 2.510 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.130 inches minimum and 0.150 inches maximum
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
4 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
39.7 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Ultimate Trip Time Per Pole In Seconds
0.090 nominal single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.035 nominal at 200 pct and 0.025 nominal at 300 pct single location
Inclosure Protection Type For Which Designed
explosion resistant
Unpackaged Unit Weight
4.250 ounces nominal
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
71-103F120AC39-75ACURVE5X Circuit Breaker
AM2-Z354-2 Circuit Breaker
SM-C-364203 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-752-4110?
The FSCG of the NSN 5925-00-752-4110 is 5925
Does the NSN 5925-00-752-4110 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-752-4110 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-752-4110 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-752-4110 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-752-4110 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

MRA14PG
5935-00-839-3468
Electrical Plug Connector
MRA14PG7
5935-00-844-4856
Electrical Receptacle Connector
MRA14PJ
5935-00-724-4195
Electrical Receptacle Connector
MRA14PJ6
5935-00-724-4195
Electrical Receptacle Connector
MRA14PJ6-436TYPE26
5935-00-849-5485
Electrical Plug Connector
MRA14PJT34
5935-00-490-5146
Electrical Receptacle Connector
MRA14PJTC6H1
5935-00-815-3377
Electrical Plug Connector
MRA14PJTY34
5935-00-490-5146
Electrical Receptacle Connector
MRA14S
5935-00-802-7980
Electrical Receptacle Connector
MRA14SAJTC6H1
5935-00-818-5853
Electrical Plug Connector
MRA14SG7H
5935-00-988-1597
Electrical Plug Connector
MRA14SGHVL
5935-00-687-1863
Electrical Plug Connector
MRA14SJ
5935-00-729-7222
Electrical Receptacle Connector
MRA14SJ6
5935-00-729-7222
Electrical Receptacle Connector
MRA14SJT
5935-00-755-0754
Electrical Plug Connector