1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-601-0583

5925-00-601-0583

Find complete technical information, availability, and procurement data for: 5925-00-601-0583

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-601-0583 to receive an up to date pricing and availability quote by email.

5925-00-601-0583
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-601-0583
Item Name Code
00136
Assigment Date
01/01/1961 (65 years ago)

0.704 inches nominal center to center distance between terminals parallel to length, 0.750 inches maximum body width, 0.250 inches nominal bushing length, 2.189 inches maximum body length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.250 inches nominal
Body Length
2.189 inches maximum
Body Width
0.750 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.704 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.860 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac and 35.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac and 6000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.469 inches
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct and 5.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
vibration resistant and shock resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Unpackaged Unit Weight
43.0 grams nominal
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
uns
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
613540-13 Circuit Breaker
700-029-35 Circuit Breaker
MP707 Circuit Breaker
MP707D Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-601-0583?
The FSCG of the NSN 5925-00-601-0583 is 5925
Does the NSN 5925-00-601-0583 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-601-0583 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-601-0583 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-601-0583 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-601-0583 was assigned to the Federal Catalog?
It was assigned 65 years ago, on Sun, Jan 1, 1961

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

215062
5810-01-452-3267
Microcircuit Programmer Adapter
2150627
2520-00-447-2315
Shaft Assy
21506271
2590-01-696-7170
Vehicular Components Bracket
21506272
2590-01-696-7170
Vehicular Components Bracket
21506272151
2520-00-447-2315
Shaft Assy
2150628
2520-00-700-0750
Vehicular Propeller Shaft
215063
5810-01-452-3269
Microcircuit Programmer Adapter
215063-001
5365-01-708-3893
Straight Spacer
2150630
5340-01-416-0499
Access Cover
2150641
2520-00-734-2369
Vehicular Clutch Disk
215064PC19
5331-00-067-4877
O-Ring
215065
4720-01-618-0986
Nonmetallic Hose Assembly
215065-222
4820-00-732-4605
Valve Assembly
21506563
4710-01-692-7857
Metallic Bent Tube
215065ITEM46
5340-00-793-0592
Self-Locking Insert