5925-00-549-5362

Find complete technical information, availability, and procurement data for: 5925-00-549-5362

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-549-5362 to receive an up to date pricing and availability quote by email.

5925-00-549-5362
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-549-5362
Item Name Code
00136
Assigment Date
01/01/1963 (63 years ago)

An item of neckwear, of varying lengths and widths, worn loosely about the neck in various ways for warmth or decorative purposes.

2.313 inches nominal body height, 0.969 inches nominal body width, single pole type body style, moderately rugged fragility factor, 3.500 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
3.500 inches nominal
Body Width
0.969 inches nominal
Body Height
2.313 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.188 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
1 terminal and 1 clip
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac and 35.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 125.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac and 2500.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal-magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct and 210.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
shockproof and vibrationproof
Trip Release Ambient Temp Rating
50.0 celsius nominal single location
Frequency In Hertz
400.0 single location
Material
plastic case
Precious Material And Location
contact surfaces silver
Precious Material
silver
Test Data Document
"81349-mil-c-17588 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
1 compression and 1 quick disconnect, female

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
454D507G07 Circuit Breaker
ETN1076 Circuit Breaker
S6205-3232365REVCCLASSALB1-35AMP Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-549-5362?
The FSCG of the NSN 5925-00-549-5362 is 5925
Does the NSN 5925-00-549-5362 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-549-5362 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-549-5362 contain precious materials?
Item contains silver.
Does NSN 5925-00-549-5362 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-549-5362 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

6R121
6850-01-222-8799
Direct Electrostatic Proce Toner
6R122
5210-01-428-5358
Line Level
6R123
5210-01-428-5542
Level and Plumb
6R124
5210-01-428-5528
Level and Plumb
6R1278
7510-01-566-6693
Toner Cartridge
6R128
5210-01-428-5550
Level and Plumb
6R130
6850-01-068-6526
Direct Electrostatic Proce Toner
6R1317
5340-01-471-5176
Block Clamp
6R135
6850-01-341-5065
Indirect Electrostatic Pro Toner
6R136
5210-01-428-5565
Level and Plumb
6R139
6850-01-231-5696
Direct Electrostatic Proce Toner
6R1402
4130-00-575-5018
Tie Rod Assy
6R149
6850-00-926-5291
Direct Electrostatic Proce Toner
6R150
5210-01-428-5559
Carpenter's Square
6R1502
5995-01-033-3880
Electrical Power Cable Assembly