507-250-103

View detailed technical data, stock status, and sourcing information for: 507-250-103

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 507-250-103 to receive an up to date pricing and availability quote by email.

507-250-103
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-543-7342
Item Name Code
00136
Assigment Date
09/28/1974 (51 years ago)

0.704 inches nominal center to center distance between terminals parallel to length, 0.250 inches nominal bushing length, single pole type body style, 0.750 inches maximum body width, 1.094 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.250 inches nominal
Body Length
1.094 inches maximum
Body Width
0.750 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.704 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.840 inches maximum
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac and 50.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac and 32.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac and 6000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.469 inches
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct and 40.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Unpackaged Unit Weight
2.000 ounces nominal
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
uns
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
30-072-1 Circuit Breaker
507-250-103 Circuit Breaker
MP-708H Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-543-7342?
The FSCG of the NSN 5925-00-543-7342 is 5925
Does the NSN 5925-00-543-7342 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-543-7342 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-543-7342 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-543-7342 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-543-7342 was assigned to the Federal Catalog?
It was assigned 51 years ago, on Sat, Sep 28, 1974

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

FLEX C-41 SM TANK FNL RINSE
6750-01-443-3345
Photographic Stabilizer
FLEX CA
6550-01-299-1694
Calcium Determination Test Pack
FLEX CHIP 630/835
5610-01-534-1289
Deck and Floor Covering Surface
FLEX CKMB
6550-01-331-5459
Creatine Kinase Determ Test Pack
FLEX CLAMP
2020-01-664-3004
Gooseneck Assembly
FLEX DBIL
6550-01-320-0229
Direct Bilirubin Deter Test Pack
FLEX-EL
6515-01-175-4199
Electrocardiograph Electrode
FLEX-EL,COLONIAL HOSPITAL SUPPLY
6515-01-175-4199
Electrocardiograph Electrode
FLEX FLYTE
4720-00-012-5509
Air Duct Hose
FLEX FLYTE L9
4720-00-012-5509
Air Duct Hose
FLEX FR 765/735
5610-01-550-0505
Deck and Floor Covering Surface
FLEX FREESTAND-17
7025-01-580-0644
Display Unit
FLEX-FS17
7025-01-580-0644
Display Unit
FLEX-GARD H 1/4 BLK
5970-01-124-5325
Electrical Textile Sleeving
FLEX GOT
6550-01-299-1693
Aspartate Aminotransfe Test Pack