1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-403-2571

5925-00-403-2571

Find complete technical information, availability, and procurement data for: 5925-00-403-2571

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-403-2571 to receive an up to date pricing and availability quote by email.

5925-00-403-2571
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-403-2571
Item Name Code
00136
Assigment Date
06/05/1970 (56 years ago)

4.125 inches nominal body width, 5.562 inches nominal center to center distance between terminals parallel to length, 6.500 inches nominal body length, multipole-single actuator type body style, 3.375 inches nominal body height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
6.500 inches nominal
Body Width
4.125 inches nominal
Body Height
3.375 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.562 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
Unthreaded Mounting Hole Diameter
0.188 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.938 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
Boss Height
0.125 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac and 20.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100000.0 ac and 100000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
instantaneous and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
50.000 minimum at 200 pct and 130.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
50.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
4968D87G13 Circuit Breaker
FA3020PV Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-403-2571?
The FSCG of the NSN 5925-00-403-2571 is 5925
Does the NSN 5925-00-403-2571 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-403-2571 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-403-2571 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-403-2571 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-403-2571 was assigned to the Federal Catalog?
It was assigned 56 years ago, on Fri, Jun 5, 1970

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

32065
4130-00-586-0412
Bumper
3206500000
5330-01-205-7971
Seal
320651-2
4810-01-595-7404
Butterfly Valve
3206514-1
4330-01-372-9744
Fluid Filter Element
320652
1220-00-624-8479
Board Assy
3206522
7610-01-561-3601
Book
3206530-1
5342-01-049-9059
Plunger
3206530-2
5342-01-050-3757
Plunger
3206530-5
5315-01-084-4401
Headless Shoulder Pin
3206530-6
5342-01-067-3123
Plunger
3206531
5342-01-050-3758
Handle
320654
1220-00-624-8480
Board Assy
320655
3110-00-155-6661
Annular Ball Bearing
3206551
5340-01-596-1601
Access Cover
3206555
4720-01-373-0480
Nonmetallic Hose Assembly