DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part PDLA-105 to receive an up to date pricing and availability quote by email.

PDLA-105
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-295-5460
Item Name Code
00136
Assigment Date
01/01/1963 (63 years ago)

single pole type body style, 3.160 inches nominal overall length, 0.195 inches minimum and 0.225 inches maximum unthreaded mounting hole diameter, 1.880 inches nominal body width, 1.060 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Overall Length
3.160 inches nominal
Body Width
1.880 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.060 inches nominal
Unthreaded Mounting Hole Diameter
0.195 inches minimum and 0.225 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.406 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.000 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
2 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
105.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
automatic
Internal Trip Release Configuration
series trip single location
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 minimum at 200 pct and 50.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
vibration resistant and shock resistant and salt spray proof and fungus resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Material
plastic case
Terminal Type And Quantity
2 threaded stud

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-026-4758 No Name Available 09/27/1967
5925-00-849-8943 No Name Available 10/10/1969

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
12387864-1 Circuit Breaker
5925002955460 Circuit Breaker
7392441 Circuit Breaker
AA55571/07-009 Circuit Breaker
M13516/7-9 Circuit Breaker
M13516/7BII-105 Circuit Breaker
MS39068-4 Circuit Breaker
PDLA-105 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-295-5460?
The FSCG of the NSN 5925-00-295-5460 is 5925
Does the NSN 5925-00-295-5460 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-295-5460 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-295-5460 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-295-5460 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-295-5460 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

U5532C-550
6625-01-687-5845
Current Sensor
U553C-526
6625-01-607-3042
Current Sensor
U553MS
5910-00-681-1722
Electrolytic Fixed Capacitor
U555
3110-00-144-8549
Annular Ball Bearing
U5551045
5330-01-553-9671
Plain Seal
U5589-Z11P001
5310-01-694-7340
Aircraft Equipment Nut
U55908070
5950-01-414-8706
Power Transformer
U56-A
1260-01-181-5895
Gimbal Drive System
U560-9
5340-01-161-9189
Beam Gripping Clamp
U5600
5120-00-988-3629
Mechanical Puller
U5600X
5120-00-988-3629
Mechanical Puller
U5601
5220-00-989-2067
Profile Gage
U562-0120
5310-01-123-3336
Spring Tension Washer
U562-0120-S
5310-01-234-9424
Spring Tension Washer
U5635B
5950-00-231-4876
Audio Frequency Transformer