DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-259-5682 to receive an up to date pricing and availability quote by email.

5925-00-259-5682
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-259-5682
Item Name Code
00136
Assigment Date
07/04/1973 (53 years ago)

1.468 inches minimum and 1.532 inches maximum body width, 1.985 inches minimum and 2.015 inches maximum body length, 1.555 inches minimum and 1.565 inches maximum center to center distance between terminals parallel to length, multipole-multiple actuator type body style, 0.745 inches minimum and 0.755 inches maximum center to center distance between terminals parallel to width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
1.985 inches minimum and 2.015 inches maximum
Body Width
1.468 inches minimum and 1.532 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.555 inches minimum and 1.565 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.745 inches minimum and 0.755 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.655 inches minimum and 1.665 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.745 inches minimum and 0.755 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.125 inches minimum and 0.135 inches maximum
Mounting Surface To Terminal End Distance
1.835 inches minimum and 1.845 inches maximum
Pole Quantity
2
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
4 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
2 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one and two linked
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Inclosure Protection Type For Which Designed
dustproof and fungus proof
Frequency In Hertz
60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
4 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
JA2-A3-A-20-P Circuit Breaker
JA2S-A3-A-20-P Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-259-5682?
The FSCG of the NSN 5925-00-259-5682 is 5925
Does the NSN 5925-00-259-5682 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-259-5682 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-259-5682 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-259-5682 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-259-5682 was assigned to the Federal Catalog?
It was assigned 53 years ago, on Wed, Jul 4, 1973

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

H851-2001-379
9330-01-708-9770
Plastic Strip
H851-2001-380
9330-01-708-9679
Plastic Strip
H851-2001-381
9330-01-709-0076
Plastic Strip
H851-2001-383
5340-01-709-0172
Access Cover
H851-2001-40
5935-01-239-0796
Electrical Receptacle Connector
H851-2001-401
5340-01-499-2169
Cable Retractor
H851-2001-402
5340-01-516-7322
Cable Retractor
H851-2001-411
5935-01-497-3520
Electrical Receptacle Connector
H851-2001-426
6260-01-556-1663
Dummy Lamp
H851-2001-48
5935-01-229-7203
Electrical Receptacle Connector
H851-2001-50
5935-01-238-9061
Electrical Receptacle Connector
H851-2001-93
5925-01-497-1061
Circuit Breaker
H851-2001-94
5925-01-497-1094
Circuit Breaker
H851-2001-95
5925-01-497-1097
Circuit Breaker
H851-2001-96
5925-01-497-1175
Circuit Breaker