DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-229-7323 to receive an up to date pricing and availability quote by email.

5925-00-229-7323
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-229-7323
Item Name Code
00136
Assigment Date
03/05/1971 (55 years ago)

single pole type body style, 1.655 inches minimum and 1.665 inches maximum distance between centerlines of mounting facilities parallel to body length, 0.745 inches minimum and 0.755 inches maximum body width, 1.555 inches minimum and 1.565 inches maximum center to center distance between terminals parallel to length, 1.985 inches minimum and 2.015 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
1.985 inches minimum and 2.015 inches maximum
Body Width
0.745 inches minimum and 0.755 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.555 inches minimum and 1.565 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.655 inches minimum and 1.665 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.125 inches minimum and 0.135 inches maximum
Mounting Surface To Terminal End Distance
1.875 inches minimum and 1.885 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Unpackaged Unit Weight
2.500 ounces nominal
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 quick disconnect, male

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
JA1-C3-10-2 Circuit Breaker
SK683260-7 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-229-7323?
The FSCG of the NSN 5925-00-229-7323 is 5925
Does the NSN 5925-00-229-7323 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-229-7323 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-229-7323 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-229-7323 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-229-7323 was assigned to the Federal Catalog?
It was assigned 55 years ago, on Fri, Mar 5, 1971

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

1348161
4210-01-518-0463
Ported Valve Ball
1348162
4210-01-568-6904
Ported Valve Ball
1348163
4810-01-521-0501
Ported Valve Ball
1348165
4810-01-517-4987
Ball Valve
1348166
4210-01-518-0478
Ported Valve Ball
1348167
4210-01-518-0480
Ported Valve Ball
1348169
4810-01-517-4985
Ball Valve
134817
5930-00-987-0114
Rotary Switch
134818
3030-00-253-8331
V Belt
134818-01
6610-00-724-0382
Index Bank
13481B
5950-00-243-5747
Power Transformer
13482
5306-00-226-4830
Machine Bolt
13482-0-5
4820-01-387-4014
Fluid Valve Stem
13482-022
5930-01-417-6587
Push Switch
13482-023
5930-01-417-3112
Electrical Switch Cover