DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-229-1482 to receive an up to date pricing and availability quote by email.

5925-00-229-1482
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-229-1482
Item Name Code
00136
Assigment Date
02/19/1969 (57 years ago)

single pole type body style, 0.332 inches minimum and 0.375 inches maximum bushing length, 0.625 inches maximum body width, +0.3503 to 0.3537 inches thread pitch diameters, 1.500 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.3503 to 0.3537 inches
Body Style
single pole type
Bushing Length
0.332 inches minimum and 0.375 inches maximum
Body Length
1.500 inches maximum
Body Width
0.625 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.844 inches minimum and 0.906 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.605 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
4.5 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.070 minimum at 200 pct and 0.700 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
hermetically sealed and shockproof and vibrationproof and salt spray proof and humidity proof and sandtight and dustproof
Unpackaged Unit Weight
1.800 ounces nominal
Test Data Document
87557-2595d1036 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
unef
Terminal Type And Quantity
2 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
2595D1036-5 Circuit Breaker
AP1-160-5 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-229-1482?
The FSCG of the NSN 5925-00-229-1482 is 5925
Does the NSN 5925-00-229-1482 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-229-1482 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-229-1482 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-229-1482 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-229-1482 was assigned to the Federal Catalog?
It was assigned 57 years ago, on Wed, Feb 19, 1969

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

570-4466-01
5340-01-662-8777
Mounting Plate
570 4476
2815-00-410-1236
Piston Ring Set
570 4477
2815-00-410-1248
Piston Ring Set
570-4587-01
5120-01-346-6922
Bearing and Bushing Inserter
570-4587-02
3465-01-211-8957
Arbor Press Fixture
570-4588-02
5120-01-210-3430
Bearing and Bushing Inserter
570-4660-01
6635-01-662-8778
Dynamic-Static Balancing Machine
570-46B
5910-00-113-5562
Ceramic Dielectr Fixed Capacitor
570-4745-01
6625-01-662-8771
Electrical-Electron Test Fixture
570-476
6130-01-139-5979
Power Supply
570-478
6130-01-139-5980
Power Supply
570-484
8475-00-461-5159
Dual Visor Assy
570-484PC03
4710-00-369-2596
Nonmetallic Tubing
570-485
8475-00-461-5166
Dual Visor Kit
570-487
6625-00-309-0500
Electrical Frequency Meter