DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-182-7452 to receive an up to date pricing and availability quote by email.

5925-00-182-7452
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-182-7452
Item Name Code
00136
Assigment Date
03/07/1973 (53 years ago)

+0.1177 to 0.1214 inches thread pitch diameters, 1.940 inches nominal center to center distance between terminals parallel to length, single pole type body style, 2.480 inches minimum and 2.500 inches maximum body length, 0.750 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.1177 to 0.1214 inches
Body Style
single pole type
Body Length
2.480 inches minimum and 2.500 inches maximum
Body Width
0.750 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.150 inches nominal
Mounting Surface To Terminal End Distance
2.475 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
50.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.135 minimum at 200 pct and 1.650 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
moisture resistant and shock resistant and vibration resistant
Material
plastic case
Test Data Document
"81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud
Specification/Standard Data
81349-mil-c-55629/1 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-755-8623 No Name Available 06/26/2013
5925-00-863-2366 No Name Available 05/01/1985
5925-00-929-7863 No Name Available 08/01/1984

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
133-250-101 Circuit Breaker
4MC1-7-50 Circuit Breaker
64A92C811-2 Circuit Breaker
7900051-054 Circuit Breaker
AM1-B3-A-50-3 Circuit Breaker
AM1-Z21-128 Circuit Breaker
AM12MG6 Circuit Breaker
AM12MG6-50-30-5-DC Circuit Breaker
AM12MG6-50-30DC5 Circuit Breaker
AM12MG6-50A Circuit Breaker
APL-1-1-51-503-M Circuit Breaker
APL1-51-50AMP Circuit Breaker
APL1-55629-1-128 Circuit Breaker
M55629/1-128 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-182-7452?
The FSCG of the NSN 5925-00-182-7452 is 5925
Does the NSN 5925-00-182-7452 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-182-7452 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-182-7452 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-182-7452 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-182-7452 was assigned to the Federal Catalog?
It was assigned 53 years ago, on Wed, Mar 7, 1973

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

0317.1005.C
6685-01-417-4159
Scale Plate
0317.1005.C 0-20PSI
6685-01-492-4295
Pressure Indicator Subassembly
0317.1005.C 0-80PSI
6685-01-492-4293
Pressure Indicator Subassembly
0317-1005C
6685-01-597-2672
Plate White Scale
0317-3840
5910-00-070-9109
Ceramic Dielectr Fixed Capacitor
0317-5004
6680-00-147-2765
Flow Rate Indicating Meter
0317-5005
6680-00-103-6813
Flow Rate Indicating Meter
0317-5006
6680-00-879-4531
Flow Rate Indicating Meter
0317-5011
6680-00-725-3332
Flow Rate Indicating Meter
0317-5110
5910-00-903-8738
Mica Dielectric Fixed Capacitor
0317-5190
5910-00-227-7777
Mica Dielectric Fixed Capacitor
0317-5280
5910-00-227-7771
Capacitor
0317-BB1
5310-01-576-0705
Flat Washer
0317-BB1-001
5310-01-605-8726
Flat Washer
0317-BB1-005
5310-01-576-0705
Flat Washer