1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-181-3833

5925-00-181-3833

Find complete technical information, availability, and procurement data for: 5925-00-181-3833

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-181-3833 to receive an up to date pricing and availability quote by email.

5925-00-181-3833
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-181-3833
Item Name Code
00136
Assigment Date
03/02/1973 (53 years ago)

1.940 inches nominal center to center distance between terminals parallel to length, +0.1177 to 0.1214 inches thread pitch diameters, single pole type body style, 2.480 inches minimum and 2.500 inches maximum body length, 0.750 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.1177 to 0.1214 inches
Body Style
single pole type
Body Length
2.480 inches minimum and 2.500 inches maximum
Body Width
0.750 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.150 inches nominal
Mounting Surface To Terminal End Distance
2.475 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
shunt trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct and 100.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
moisture resistant and salt spray proof and shock resistant and vibration resistant
Unpackaged Unit Weight
3.700 ounces nominal
Frequency In Hertz
50.0 or 60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
3 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
APL-1-3-66-153 Circuit Breaker
P50119ITEM1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-181-3833?
The FSCG of the NSN 5925-00-181-3833 is 5925
Does the NSN 5925-00-181-3833 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-181-3833 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-181-3833 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-181-3833 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-181-3833 was assigned to the Federal Catalog?
It was assigned 53 years ago, on Fri, Mar 2, 1973

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

11002405
5999-01-417-6575
Electrical Contact
11002407
5340-01-417-8536
Spring Tension Clip
11002409
5895-01-477-5465
Multiplexer
11002409-1
5895-01-486-7862
Multiplexer
1100241
5310-01-488-3956
Lock Washer
11002410-1
5962-01-102-3840
Linear Microcircuit
11002412-1
5962-01-103-5073
Linear Microcircuit
11002415-1
5962-01-286-2238
Linear Microcircuit
1100242
5310-01-456-5616
Lock Washer
11002421-1
5962-01-070-6595
Digital Microcircuit
11002426-1
5962-01-129-7255
Linear Microcircuit
11002430-1
5935-01-339-1334
Electrical Receptacle Connector
11002433-1
9320-01-417-8109
Rubber Strip
1100246
5340-01-325-2387
Chassis Quick Disc
11002461
5310-01-097-8026
Flat Washer