1. Home /
  2. Catalog /
  3. Capacitors /
  4. 5910-01-277-2911

5910-01-277-2911

Find complete technical information, availability, and procurement data for: 5910-01-277-2911

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5910-01-277-2911 to receive an up to date pricing and availability quote by email.

5910-01-277-2911
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5910 Capacitors
National Stock Number
5910-01-277-2911
Item Name Code
00007
Assigment Date
04/20/1988 (38 years ago)

A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see capacitor, fixed, metallized, paper-plastic dielectric.

not established reliability indicator, 1.250 inches minimum terminal length, 0.156 inches maximum body length, 0.705 inches maximum body diameter, w/o mtg facilities, radial terminals body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
w/o mtg facilities, radial terminals
Reliability Indicator
not established
Terminal Length
1.250 inches minimum
Body Diameter
0.705 inches maximum
Body Length
0.156 inches maximum
Center To Center Distance Between Terminals Parallel To Diameter
0.375 inches nominal
Terminal Diameter
0.025 inches nominal
Schematic Diagram Designator
no common or grounded electrode(s)
Capacitance Value Per Section
0.010 picofarads single section
Voltage Temp Limits Per Section In Percent Capacitance Change
-56.0 to 22.0 without voltage applied single section
Nonderated Operating Temp
10.0 celsius minimum and 85.0 celsius maximum
Nonderated Continuous Voltage Rating And Type Per Section
150.0 ac-rms single section and 1000.0 dc single section
Tolerance Range Per Section
-20.00 to 20.00 percent single section
Insulation Resistance At Reference Temp
20000.0 megohms
Dissipation Factor At Reference Temp In Percent
2.500
Terminal Surface Treatment
solder
Material
plastic case
Terminal Type And Quantity
2 uninsulated wire lead

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
102027-049 Ceramic Dielectr Fixed Capacitor

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5910-01-277-2911?
The FSCG of the NSN 5910-01-277-2911 is 5910
Does the NSN 5910-01-277-2911 have a Schedule B code assigned?
Yes, the Schedule B code is 8532290040
Does NSN 5910-01-277-2911 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5910-01-277-2911 contain precious materials?
Item does not contain precious metal.
Does NSN 5910-01-277-2911 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5910-01-277-2911 was assigned to the Federal Catalog?
It was assigned 38 years ago, on Wed, Apr 20, 1988

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

DAA3285P001-319
1660-01-424-0446
Air Conditioning-H Duct Assembly
DAA3285P001-320
1660-01-424-8556
Air Conditioning-H Duct Assembly
DAA3285P001-321
1660-01-424-8558
Air Conditioning-H Duct Assembly
DAA3285P001-323
1660-01-424-0447
Air Conditioning-H Duct Assembly
DAA3285P001-324
1660-01-424-0449
Air Conditioning-H Duct Assembly
DAA3285P001-325
1660-01-424-0450
Air Conditioning-H Duct Assembly
DAA3285P001-326
1660-01-424-0451
Air Conditioning-H Duct Assembly
DAA3285P002-223
6340-01-263-3639
Fire Detector Sy Sensing Element
DAA3285P002-225
6340-01-263-7511
Fire Detector Sy Sensing Element
DAA3285P002-229
1680-01-262-9940
Fire-Leak Control Unit
DAA3285P002-233
1680-01-263-7513
Sensing Element
DAA3285P002-235
6340-01-264-4139
Fire Detector Sy Sensing Element
DAA3285P002-239
6340-01-263-7515
Fire Detector Sy Sensing Element
DAA3285P002-241
1680-01-263-7516
Fire-Leak Control Unit
DAA3285P002-243
6340-01-263-7517
Fire Detector Sy Sensing Element