906012-36

View detailed technical data, stock status, and sourcing information for: 906012-36

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 906012-36 to receive an up to date pricing and availability quote by email.

906012-36
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5910 Capacitors
National Stock Number
5910-01-271-1702
Item Name Code
00008
Assigment Date
01/20/1988 (38 years ago)

A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

established reliability indicator, 1.500 inches nominal terminal length, n-3 mil-std-1276 wire lead type designator, w/o mtg facilities, axial terminals body style, 0.001 reliability failure rate level in percent

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
w/o mtg facilities, axial terminals
Mil-Std-1276 Wire Lead Type Designator
n-3
Reliability Indicator
established
Reliability Failure Rate Level In Percent
0.001
Terminal Length
1.500 inches nominal
Body Diameter
0.192 inches minimum and 0.217 inches maximum
Body Length
0.955 inches nominal
Terminal Diameter
0.020 inches nominal
Schematic Diagram Designator
no common or grounded electrode(s)
Anode Type
solid
Electrical Polarization
nonpolarized
Features Provided
hermetically sealed case
Capacitance Value Per Section
1.900 microfarads single section
Nonderated Operating Temp
-55.0 celsius minimum and 85.0 celsius maximum
Nonderated Continuous Voltage Rating And Type Per Section
50.0 dc single section
Criticality Code Justification
feat
Tolerance Range Per Section
-10.00 to 10.00 percent single section
Capacitive Electrode Material
tantalum
Dissipation Factor At Reference Temp In Percent
4.000
Dc Leakage At Reference Temp
1.500 microamperes
Case Insulation Material
plastic
Special Features
weibull graded failure rate
Test Data Document
"81349-mil-c-39003 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
2 uninsulated wire lead
Specification/Standard Data
81349-mil-c-39003/4 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5910-00-725-0349 No Name Available 11/01/2007
5910-00-877-8899 No Name Available 02/01/1998
5910-00-912-6496 No Name Available 12/01/2007
5910-01-069-4983 No Name Available 02/01/2008

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
108-235-5361 Electrolytic Fixed Capacitor
151D195X9035X2 Electrolytic Fixed Capacitor
906012-36 Electrolytic Fixed Capacitor
D1R9BN35KI Electrolytic Fixed Capacitor
K1R9N35KN2 Electrolytic Fixed Capacitor
K1R9N50KNS Electrolytic Fixed Capacitor
K1R9N50KS Electrolytic Fixed Capacitor
M39003/04-1221 Electrolytic Fixed Capacitor
M39003/04-1431 Electrolytic Fixed Capacitor
M39003/04-3127 Electrolytic Fixed Capacitor
M39003/04-5127 Electrolytic Fixed Capacitor
T111B195K050AS Electrolytic Fixed Capacitor

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5910-01-271-1702?
The FSCG of the NSN 5910-01-271-1702 is 5910
Does the NSN 5910-01-271-1702 have a Schedule B code assigned?
Yes, the Schedule B code is 8532290040
Does NSN 5910-01-271-1702 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5910-01-271-1702 contain precious materials?
Item does not contain precious metal.
Does NSN 5910-01-271-1702 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5910-01-271-1702 was assigned to the Federal Catalog?
It was assigned 38 years ago, on Wed, Jan 20, 1988

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

6680PL1286903
6680-01-239-5702
Nonself-Gene Electric Tachometer
6680PL1295433
6680-01-186-6611
Flow Rate Indicating Meter
6680PL1327916
6680-01-179-6417
Meter Tube
6680PL1331644
6680-01-194-1238
Liquid Sight Indicator
6680PL1353025
6680-01-128-3930
Linear Electrical Accelerometer
6680PL1376577
6680-00-890-2920
Float Switch Load Pack
6680PL1379536
6680-00-601-1322
Vib. Transducer
6680PL1379561
6680-00-610-2529
Air Filter Indicator
6680PL1390332
6680-01-072-2794
Liquid Level Switch
6680PL1422392
6680-01-177-9448
Float Type Liquid Quantity Gage
6680PL1479520
6680-00-091-9718
Flexible Shaft Assembly
6680PL1501068
6680-01-554-4741
Tachometer Generator
6680PL1598702
6680-01-576-4521
Liquid Quantity Transmitter
6680PL1611668
6680-01-060-4248
Liquid Quantity Indicator
6680PL1620708
6680-01-048-2998
Liquid Quantity Indicator