900098-004

View detailed technical data, stock status, and sourcing information for: 900098-004

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 900098-004 to receive an up to date pricing and availability quote by email.

900098-004
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5910 Capacitors
National Stock Number
5910-01-038-7911
Item Name Code
00005
Assigment Date
04/11/1977 (49 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

w/o mtg facilities terminal(s) on one surface body style, 0.0100 reliability failure rate level in percent, established reliability indicator, 1.000 inches minimum terminal length, 0.270 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
w/o mtg facilities terminal(s) on one surface
Reliability Indicator
established
Reliability Failure Rate Level In Percent
0.0100
Terminal Length
1.000 inches minimum
Body Length
0.270 inches maximum
Body Width
0.190 inches maximum
Body Height
0.110 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.120 inches nominal
Terminal Diameter
0.016 inches nominal
Schematic Diagram Designator
no common or grounded electrode(s)
Insulation Resistance At Maximum Operating Temp
10000.0 megohms
Capacitance Value Per Section
4.000 picofarads single section
Nonderated Operating Temp
-55.0 celsius minimum and 125.0 celsius maximum
Nonderated Continuous Voltage Rating And Type Per Section
300.0 dc single section
Temp Coefficient Of Capacitance Range Per Section In Ppm Per Deg Celsius
-200.0 to 200.0 single section
Tolerance Range Per Section
-0.50 to 0.50 picofarads single section
Insulation Resistance At Reference Temp
100000.0 megohms
Terminal Surface Treatment
solder
Material
plastic case
Test Data Document
"81349-mil-c-39001 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
2 uninsulated wire lead
Specification/Standard Data
81349-mil-c-0039001/5 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5910-00-004-5995 No Name Available 07/01/1987

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
900098-004 Mica Dielectric Fixed Capacitor
CD5CC040D0 Mica Dielectric Fixed Capacitor
CK5CC040D0 Mica Dielectric Fixed Capacitor
CMR03C040D0CL Mica Dielectric Fixed Capacitor
CMR03C040D0CM Mica Dielectric Fixed Capacitor
CMR03C4R0D0CP Mica Dielectric Fixed Capacitor
CMR03C4R0DOCR Mica Dielectric Fixed Capacitor
CMR03C4R0J0CM Mica Dielectric Fixed Capacitor
DM5-040K Mica Dielectric Fixed Capacitor
DM5C040D03001CRT Mica Dielectric Fixed Capacitor
DM5C040J0100WV4CR Mica Dielectric Fixed Capacitor
DM5CC040D Mica Dielectric Fixed Capacitor

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5910-01-038-7911?
The FSCG of the NSN 5910-01-038-7911 is 5910
Does the NSN 5910-01-038-7911 have a Schedule B code assigned?
Yes, the Schedule B code is 8532290020
Does NSN 5910-01-038-7911 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5910-01-038-7911 contain precious materials?
Item does not contain precious metal.
Does NSN 5910-01-038-7911 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5910-01-038-7911 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Mon, Apr 11, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

222-10NL-2223306
5930-01-282-5437
Thermostatic Switch
222-10NL-2223309
5930-01-281-6895
Thermostatic Switch
222-10NL-2223314
5930-01-262-6841
Thermostatic Switch
222-10NL-2223333
5930-01-290-5206
Thermostatic Switch
222-10NL-2223333/2507100
5930-01-290-5206
Thermostatic Switch
222-10NL-2223351
5930-01-370-0922
Thermostatic Switch
222-10NL-2223352
5930-01-370-0921
Thermostatic Switch
222-10NL-2223389
5930-01-358-9970
Thermostatic Switch
222-10NL-2223417
5930-01-360-2774
Thermostatic Switch
222-10NL-2223448
5930-01-355-7100
Pressure-Thermostatic Switch
222-10NL-2223452
5930-01-307-6704
Thermostatic Switch
222-10NL-2223455
5930-01-655-8652
Thermostatic Switch
222-10NL-2223480
5930-01-370-4014
Thermostatic Switch
222-10NL-2223562
5930-01-311-5842
Thermostatic Switch
222-10NL-2223607
5930-01-473-8648
Pressure Switch