1. Home /
  2. Catalog /
  3. Capacitors /
  4. 5910-00-686-7881

5910-00-686-7881

Find complete technical information, availability, and procurement data for: 5910-00-686-7881

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5910-00-686-7881 to receive an up to date pricing and availability quote by email.

5910-00-686-7881
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5910 Capacitors
National Stock Number
5910-00-686-7881
Item Name Code
00007
Assigment Date
01/01/1961 (65 years ago)

0.290 inches maximum body diameter, 0.156 inches maximum body length, not established reliability indicator, w/o mtg facilities, radial terminals body style, 1.500 inches minimum terminal length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
w/o mtg facilities, radial terminals
Reliability Indicator
not established
Terminal Length
1.500 inches minimum
Body Diameter
0.290 inches maximum
Body Length
0.156 inches maximum
Center To Center Distance Between Terminals Parallel To Diameter
0.250 inches nominal
Schematic Diagram Designator
no common or grounded electrode(s)
Capacitance Value Per Section
180.000 picofarads single section
Nonderated Operating Temp
-55.0 celsius minimum and 85.0 celsius maximum
Temp Coefficient Of Capacitance Per Section In Ppm Per Deg Celsius
3300.0 single section
Nonderated Continuous Voltage Rating And Type Per Section
600.0 dc single section
Tolerance Of Temp Coefficient Per Section In Ppm Per Deg Celsius
-2500.0 to 2500.0 single section
Tolerance Range Per Section
-10.00 to 10.00 percent single section
Dissipation Factor At Reference Temp In Percent
0.600
Terminal Surface Treatment
solder
Material
ceramic case
Terminal Type And Quantity
2 uninsulated wire lead

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5910-00-064-9106 No Name Available 09/16/1968
5910-00-786-6420 No Name Available 07/24/1968
5910-00-914-2301 No Name Available 04/01/1987

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
105890 Ceramic Dielectr Fixed Capacitor
1501-105890 Ceramic Dielectr Fixed Capacitor
2DDT60N181K Ceramic Dielectr Fixed Capacitor
808-000-S3N0-181K Ceramic Dielectr Fixed Capacitor
BB60181KS3N Ceramic Dielectr Fixed Capacitor
DD-181 Ceramic Dielectr Fixed Capacitor
DD61B10N2200181JKV Ceramic Dielectr Fixed Capacitor
JF105890 Ceramic Dielectr Fixed Capacitor

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5910-00-686-7881?
The FSCG of the NSN 5910-00-686-7881 is 5910
Does the NSN 5910-00-686-7881 have a Schedule B code assigned?
Yes, the Schedule B code is 8532290040
Does NSN 5910-00-686-7881 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5910-00-686-7881 contain precious materials?
Precious metal content is unknown
Does NSN 5910-00-686-7881 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5910-00-686-7881 was assigned to the Federal Catalog?
It was assigned 65 years ago, on Sun, Jan 1, 1961

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

F93K212
6520-01-383-8413
Dental Artificial Stone
F93K225
6515-01-387-2313
Hypodermic Needle
F93K243
6515-01-387-4255
Utility Wound Closure Kit
F93K245
7690-01-379-1322
Label
F93K276
6640-01-384-5538
Micro Pipet
F93K281
6640-01-386-5161
Laboratory Inoculating Loop
F93K309
6550-01-384-7509
Diagnostic Sensitivity Discs
F93K311
6550-01-384-6568
Diagnostic Sensitivity Discs
F93K326
6550-01-387-6852
Nitrate Reduction Test Reagent
F93K332
6550-01-386-7262
Coagulation Control
F93K355
6550-01-286-6312
Cinnamaldehyde Test Reagent
F93K359
6550-01-387-6853
Voges-Proskauer Test Reagent
F93K363
6640-01-386-7860
Anaerobic Culture Appar Catalyst
F93K370
6515-01-386-7816
Vasectomy Forceps
F93K379
6515-01-386-7864
Ophthalmological Tubing Assembly