1. Home /
  2. Catalog /
  3. Capacitors /
  4. 5910-00-103-7553

5910-00-103-7553

Find complete technical information, availability, and procurement data for: 5910-00-103-7553

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5910-00-103-7553 to receive an up to date pricing and availability quote by email.

5910-00-103-7553
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5910 Capacitors
National Stock Number
5910-00-103-7553
Item Name Code
00007
Assigment Date
06/19/1968 (58 years ago)

A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

not established reliability indicator, 0.190 inches nominal body length, 0.190 inches nominal body width, 1.250 inches minimum terminal length, w/o mtg facilities terminal(s) on one surface body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
w/o mtg facilities terminal(s) on one surface
Reliability Indicator
not established
Terminal Length
1.250 inches minimum
Body Length
0.190 inches nominal
Body Width
0.190 inches nominal
Body Height
0.090 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.185 inches minimum and 0.215 inches maximum
Schematic Diagram Designator
no common or grounded electrode(s)
Capacitance Value Per Section
4700.000 picofarads single section
Voltage Temp Limits Per Section In Percent Capacitance Change
-15.0 to 15.0 without voltage applied 1st section and -25.0 to 15.0 with rated voltage applied 2nd section
Nonderated Operating Temp
-55.0 celsius minimum and 125.0 celsius maximum
Nonderated Continuous Voltage Rating And Type Per Section
100.0 dc single section
Tolerance Range Per Section
-10.00 to 10.00 percent single section
Insulation Resistance At Reference Temp
100000.0 megohms
Dissipation Factor At Reference Temp In Percent
2.5000
Terminal Surface Treatment
solder
Material
plastic case
Test Data Document
"81349-11015/18 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
2 uninsulated wire lead

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
10128075 Ceramic Dielectr Fixed Capacitor
114015-0013 Ceramic Dielectr Fixed Capacitor
352250008007 Ceramic Dielectr Fixed Capacitor
4111885-220 Ceramic Dielectr Fixed Capacitor
418291-49 Ceramic Dielectr Fixed Capacitor
420-101-021 Ceramic Dielectr Fixed Capacitor
5M.5224.220.55 Ceramic Dielectr Fixed Capacitor
99108391 Ceramic Dielectr Fixed Capacitor
B114015-0013 Ceramic Dielectr Fixed Capacitor
B95004J0049B100 Ceramic Dielectr Fixed Capacitor
Q 317 214 024 Ceramic Dielectr Fixed Capacitor
Q317214024 Ceramic Dielectr Fixed Capacitor
V2051Z6247K5 Ceramic Dielectr Fixed Capacitor

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5910-00-103-7553?
The FSCG of the NSN 5910-00-103-7553 is 5910
Does the NSN 5910-00-103-7553 have a Schedule B code assigned?
Yes, the Schedule B code is 8532290040
Does NSN 5910-00-103-7553 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5910-00-103-7553 contain precious materials?
Precious metal content is unknown
Does NSN 5910-00-103-7553 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5910-00-103-7553 was assigned to the Federal Catalog?
It was assigned 58 years ago, on Wed, Jun 19, 1968

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

205-1-1-51-2-603-M
5925-01-565-6860
Circuit Breaker
205-1-1-51-2-752-H
5925-01-497-3134
Circuit Breaker
205-1-1-52-1-103
5925-01-664-0044
Circuit Breaker
205-1-1-52-1-502-M
5925-01-230-9655
Circuit Breaker
205-1-1-52F-1-104-M
5925-01-437-4805
Circuit Breaker
205-1-1-52F-1-653
5925-01-207-7996
Circuit Breaker
205-1-1-61-1-103
5925-01-428-7349
Circuit Breaker
205-1-1-61-3-103
5925-01-426-2236
Circuit Breaker
205-1-1-61-3-502
5925-01-426-3061
Circuit Breaker
205-1-1-62-3-172
5925-01-426-3062
Circuit Breaker
205-1-1-62-3-202
5925-01-426-2232
Circuit Breaker
205-1-1-62-3-202-M
5925-01-230-9270
Circuit Breaker
205-1-1-62-3-253
5925-01-426-2230
Circuit Breaker
205-1-1-62-3-302
5925-01-426-1933
Circuit Breaker
205-1-1-62-3-303
5925-01-394-5364